top, SATTEL (THAILAND) CO., LTD.

INDUCOM RE-2X(St)YSWAY-FL


หมวดสินค้า: TKD, Germany

หมวดย่อยสินค้า: สาย Instrumentation cables: เป็นสาย High speed, Low capacitance, XLPE insulation, Capacity: max. 115 nF/km



instrumentation cable, ทนน้ำมัน,ทนความร้อน,ทนความเย็น,ราคาถูก

Application

Instrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground.

Special Feature

  • more steady at higher frequencies and temperatures (+90°C) by XLPE core insulation (cross-linked PE).
  • high crosstalk and low cable attenuation.
  • largely resistant to acids, bases and usual oils; Standard EN 50288-7.
  • protection for high mech. requirements and magnetic shield (galvanized round or flat steel-wires, additional inner sheath).
  • oil resistance: ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3.
  • Sunlight resitance: UL 1581 Section 1200.
  • flame-retardant acc. IEC 60332-1-2 and IEC 60332-3-24 (Cat. C).

Remarks

  • conform to RoHS; conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE.
  • suitable for intrinsically safe systems zone 1+2 group II acc. IEC 60079-14.
  • we are pleased to produce special versions e.g. fire-resistant (Mica), halogen-free, oiland chemical-resistant (lead sheath or GuardSheath - unleaded), BS 5308, MESC etc. >> also available as compensation cable > INDUTHERM <<.

Structure and Specifications

  • conductor material : conductor material
  • conductor class : 7-wired construction acc. to IEC 60228 cl. 2
  • core insulation : XLPE (cross-linked polyethylene)
  • core identification : pairs pairs: single-coloured with numerals: core A: black, core B: white; triple: single-coloured, core A: white, core B: red, core C: black, core A and C with numerals
  • stranding : pairs stranded in layers
  • shield : plastic clad aluminium foil (24 μm) with subjacent tinned drain wire 0.5mm² (7x0.30 mm)
  • inner sheath material : PVC, black
  • shield : galvanized round or flat steel-wires (SWA)
  • outer sheath : PVC
  • sheath colour : black or blue RAL 5015 for intrinsically safe systems
  • rated voltage : 300 V
  • testing voltage : core/core (AC/DC): 1.5 / 2 kV (duration 1 minute)
  • conductor resistance 0.5mm² : max.36.7 Ω/km; 0.75mm²: max.25.0 Ω/km; 1.3mm²: max.14.2 Ω/km
  • insulation resistance : min. 5 GΩ x km
  • current carrying capacity : acc. to DIN VDE, s. Techn. Guidelines
  • capacity : max.115 nF/km
  • inductivity : ca. 1 mH/km
  • coupling : max. 500 pF/500 m
  • other characteristics : L/R Ratio: 0.5mm²: max.25 μH/Ω; 0.75mm²: max.25 μH/Ω; 1.3mm²: max.40 μH/Ω
  • min. bending radius fixed : 10 x d
  • operat. temp. fixed min/max : -40°C / +70°C
  • operat. temp. moved min/max : -5°C / +50°C
  • burning behavior : self-extinguishing and flame-retardant acc. to IEC 60332-1-2 and IEC 60332-3-24 (Cat. C)
  • esistant to oil : ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3