สายเคเบิลโทรคมนาคม (Telecommunications cable), สายเคเบิลใยแก้วนำแสง (Fiber optic cable), สายเคเบิลอาคาร (Building cable), Self-Regulating Heating Cable, Mineral Insulated Heat Tracing, insulated wiring, PVC CABLE, overbraid, overbraided, Self-Regulating Heat Tracing, cables in thailand, sattel in thailand,betaflam,Coax Cable Thailand, MI Cable,BETAFLAM,cable,Industrial Computer thailand, references cable site PVC CABLE Wire & Cables Thermocouple cable with a choice of PVC, PTFE PFA & FG insulation, stainless steel over braid and coducter material,niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102 Elektronenstrahl-Vernetzung Tunnel, Tunnelinstallation, BETA Vernetzung Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, BETAflam? FR MI Cable / Multicore Power and Control สายไฟ ทนไฟไหม้ BETAflam? Flexible MI Comms Cables (Screened), BETAflam railway power cables and high-performance cables wide operating temperature range low smoke density STUDER CABLES, Studer, Kabel, Studer-Kabel, studerkabel, studercables schweiz, Studer Services Studer Asia Pacific, BETAflam, BETAtherm, BETAjet, BETArail, ROFLEX, BETAfixss, TRI-DELTA TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, flammwidrig, Funktionserhalt, Sicherheitskabel Spezialkabel, PVC, E 30, E 90, FE 180, FE 0 mittelspannungskabel, niederspannungskabel, netzkabel mittelspannung, niederspannung, kabelsysteme,betaflam fr,cables PVC insulated wiring Electric Heat Tracing Self-Regulating Heat Tracing MI Cable Electric Heat Tracing Snow Melting, Electric Heat Cable Electric Heat Tracing, MI Cable, Tank Heater, Self-Regulating Heating Cable, Mineral Insulated Heat Tracing MI Cable,High Temperature Exposure,High Power Outputs,High Maintain Temperatures,Thermocouple Wire Maintaining Process Fluid Temperatures, Low Watt Density Process Maintain Temperature Applications Buy Thermocouple Wire!,Bare Wire,Thermocouple Insulated Wire, Extension Grade Wire Twisted Shielded Wire Wire with Overbraiding MI Cable Multipair Thermocouple Wire Types,Duplex Insulated Thermocouple Wire,Metal Sheathed Thermocouple Wire,What is thermocouple wire? Thermocouple wire is a cable made from two dissimilar metals for the purpose of measuring temperature, Thermocouple wire is typically used to connect a thermocouple to a sensing device Data Communications and Coax Cable, wire, thermocouple wire,SLE, Insulated thermocouple wire extension grade, AWG, overbraid, overbraided Electronic Component Products that connect protect, power and switch Thermometers | Load Cells | Magnetic Flow Meters Panel Meters | Pressure Gauges | Pressure Transducers,RTD | Signal Conditioners | Strain Gauges | Temperature Controllers Temperature Labels | Temperature Measurement, Temperature Transmitters | Thermistors Thermocouple | Thermocouple Wire MINERAL INSULATED RTD CABLE MINERAL INSULATED THERMOCOUPLE CABLE สายไฟ ทนไฟไหม้ BETAflam? FR MI Cable / Single Core,สายไฟ ทนไฟไหม้ ASIA,Bangkok, Thailand,Singapore, Malaysia,Taiwan, Electricity สายไฟชนิดแบน (Ribbon or flat cable), สายไฟฟ้าบรอนซ์ (Bronze wire), niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102, MINERAL INSULATED RTD CABLE, PFA & FG insulation, stainless steel over braid and coducter material, MI Cable,High Temperature Exposure,High Power Outputs, Wire with Overbraiding, สาย USB แบบยูนิเวอร์แซล ซีเรียล บัส (Universal serial bus USB cables), สายทองแดง (Copper cable), สายไฟ ทนไฟไหม้,สายไฟ ทนไฟไหม้ สายเคเบิลไฟฟ้าสำหรับฝังดินโดยตรง (Power cable for direct burial), RTD | Signal Conditioners | Strain Gauges | Temperature Controllers, MI Cable Electric Heat Tracing, สาย USB แบบยูนิเวอร์แซล ซีเรียล บัส (Universal serial bus USB cables), Snow Melting, Electric Heat Cable, overbraid, overbraided, สายไฟ (Power cord), protect, power and switch, สายเคเบิลอาคาร (Building cable), สายไฟ ทนไฟไหม้, Tunnel, Tunnelinstallation, BETA Vernetzung, wide operating temperature range, สายไฟฟ้ารถยนต์หรือเครื่องบิน (Automotive or aircraft wire), High Maintain Temperatures,Thermocouple Wire, เครื่องบังเหียนรัดสายไฟบนแผง (Panel wiring harness), Multipair, Coax Cable Thailand, MI Cable,BETAFLAM®, สายเคเบิลอาคาร (Building cable), Electric Heat Tracing, MI Cable, Tank Heater, สายเคเบิลใช้ความร้อน (Heating cable), Temperature Labels | Temperature Measurement, สายเคเบิลอาคาร (Building cable), สาย USB แบบยูนิเวอร์แซล ซีเรียล บัส (Universal serial bus USB cables), Self-Regulating Heating Cable, Mineral Insulated Heat Tracing,
Company Profile
Products
News
Certificate
contact us
 
  
 
  
 

Home  domain names Catalog Request  domain names  Customer Support  email addresses Site References  web hosting   JOBs  web tools Links  help
Personal Domains
Products

  Thermocouple Extension Cables
    300 Volt Thermoplastic PVC
     




Applications

•  UL listed as PLTC
•  NEC Article 725
•  Suitable for Class I, Division 2 and Class II, Division 2 hazardous areas
•  300 volt rated insulation

Description

•  Conductor.......................... Solid alloy wire
•  Primary insulation.............. 15 mils (0.4 mm) 105 °C PVC
•  Color code......................... ANSI standard
•  Pair shield.......................... (Type 1802 / 1824) 100% coverage, an aluminum-polyester tape shield and a solid, tinned copper drain wire
•  Overall shield..................... (Type 1820 / 1824) 100% coverage, an aluminum-polyester tape shield and a 7-strand tinned copper drain wire
•  Jacket................................. FR-PVC, ANSI colour-coded
•  Communication wire ........... (Type 1820 / 1824) 22-AWG copper, color-coded orange

Bending Radius

•  6 x d (d = overall diameter)

Cable Type

•  1800 Single pair unshielded
•  1802 Single pair shielded
•  1820 Multiple pair overall shield
•  1824 Multiple pair individual and overall shield

Other Options

•  Manufactured in accordance with UL. Also available to ICEA, IEC, BS standards or customized configurations.
•  Various metric and AWG size conductors
•  Special color coding of insulation and jacket materials

The specifications listed above are subject to change without notice. In any change, the product's performance will remain the same, or be improved



COMPENSATING AND EXTENSION CABLES INSULATED WITH PVC

Flexible conductors insulated with PVC, flame resistant HT 150° C External sheath in flame resistant PVC HT 150°C

OVAL SHAPE


COMPENSATING AND EXTENSION CABLES INSULATED WITH SILICONE RUBBER

Flexible conductors insulated with silicone rubber External sheath in silicone rubber + 180°C


OVAL SHAPE
Additional steel braid protective jacket


COMPENSATING AND EXTENSION CABLES INSULATED WITH FIBREGLASS

Flexible conductors insulated with fibreglass or silicone External sheath in fibreglass + 250°C
OVAL SHAPE
Insulation of single conductors in fibreglass
Parallel cores Fibreglass braid jacket
External screening tin-plated copper braid jacket


Technical Data

Minimum bending radius : 7.5 x Ø(CEI 11.17)
Resistance to radiations : 8 x 10 7 KJ/kg
Temperature range : - 25 °C + 105 °C
Insulation resistance : > 1 M /km
Beahaviour in presence of flame : Non flame propagating, self extinguishing.

     
P2P
 

Nominal cross
section mm2

Number and
diameter of wires
mm

Approx outer diameter
mm

Approx. weight
kg/km

1

2x0.22
7x0.20
4.6x2.8
20
2
2x0.50
6x0.32
4.8x3.1
30
3
2x0.80
10x0.32
5.8x3.6
41
4
2x1.00
12x0.32
6.2x3.7
49
5
2x1.30
16x0.32
6.8x4.1
60
6
2x1.50
19x0.32
7.0x4.3
69


Minimum bending radius : 7.5 x Ø(CEI 11.17)
Resistance to radiations : 2 x 10 7 KJ/kg
Temperature range : - 25 °C + 105 °C
Insulation resistance : > 1 M /km
Beahaviour in presence of flame : Non flame propagating, self extinguishing.
Absence of halogens : In accordance with IEC 754-1 and VDE 0742 part 813
No development of corrosive gases (CEI 20.37)

     
S2P
P2P
 

Nominal cross
section mm2

Number and
diameter of wires
mm

Approx outer diameter
mm

Approx. weight
kg/km

Approx outer diameter
mm
Approx. weight
kg/km

1

2x0.22
7x0.20
4.6x2.8
20
5.8X4.0
28
3
2x0.80
10x0.32
5.8x3.6
41
7.1X4.7
52
6
2x1.50
19x0.32
7.0x4.3
69
8.2X5.4
85

Minimum bending radius : 7.5 x Ø(CEI 11.17)
Temperature range : - 60°C + 200°C
Temperature range : - 60°C + 250°C
Insulation resistance : > 1 M /km
Beahaviour in presence of flame : Non flame propagating, self extinguishing.
Absence of halogens : In accordance with IEC 754-1 and VDE 0742 part 813
No development of corrosive gases (CEI 20.37)

     
S5P
S5PA
V1P
 

Nominal cross
section mm2

Number and
diameter of wires
mm

Approx outer diameter
mm

Approx. weight
kg/km

Approx outer diameter
mm
Approx. weight
kg/km
Approx outer diameter
mm
Approx. weight
kg/km

1

2x0.22
7x0.20
4.1x2.4
18
4.8X3.1
28
4.1x2.6
24
2
2x0.50
6x0.32
-
-
-
-
4.5x2.8
33
3
2x0.80
10x0.32
5.2x2.8
32
5.9x3.7
52
5.0x3.0
39
4
2x1.00
12x0.32
-
-
-
-
5.2x3.1
46
5
2x1.30
16x0.32
-
-
-
-
5.6x3.3
55
6
2x1.50
19x0.32
5.9x3.2
45
6.6x3.9
75
5.8x3.4
66

 

Rating in accordance with
DIN IEC 584

Rating in accordance
with ANSI MC 96.1
-
T
TPX-TNX
T
TPX-TNX
JX
J
JPX-JNX
J
JPX-JNX
-
K
KPCA-KNCA
K
-
KCB
K
KPCB-KNCB
K
VPX-VNX
KX
K
KPX-KNX
K
KPX-KNX
-
E
EPX-ENX
E
EPX-ENX
SX / RX
S / R
S/RPCB-S/RNCB
S / R
S/RPX-S/RNX

 


Dimensions

Conductor size 0.5 mm 2 (20 AWG)

Electrical Properties

 

   Units
Screened and armoured

20 AWG / .5 mm 2

16 AWG / 1.3 mm 2

Mutual Capacitance  
Type 1800
pF/ft
pF/m
31
100
36
119
Type 1802
pF/ft
pF/m
49
160
64
210
Type 1820
pF/ft
pF/m
31
100
36
119
Type 1824
pF/ft
pF/m
49
160
64
210
Inductance (L)
pH/ft
pH/m
0.19
0.62
0.17
0.54




<< Back to Products Page