Single pair
or triad - instrumentation
cables |
| |
|
Screened
Screened
and Armoured (SWA) |
| |
|
|
|

|
 |
Applications |
These cables are applied to connect
electrical instrumentation and communication
circuits in industrial processes controls,
refineries and gas plants, chemical
and pharmaceutical industries, power
stations and electrical networks, desalination
plants and steelworks, railway and
subway signal systems, etc.
The usual
operating voltage for the above mentioned
applications is 300 V. The armoured
versions are suitable for direct burial
application.
On request, the outer
sheaths are oil, solvent and hydrocarbon
resistant, suitable for chemical and
petrochemical environments.
Physical Characteristics
Conductors : bare annealed
electrolytic copper, 7 strands according
to IEC 60228 class 2 (when wishing
to increase corrosion resistance
and operating temperature level,
we cab supply, on request, tinned
copper conductors).
| Insulation
: PVC, PE, XLPE (see Materials
Guide at page 5) |
Colour
code
:
single pair white black
single
triad white
black red
multipairs
white
black (white cores sequentially
numbered
for identification) |
Sheath
:
black
light
blue for intrinsically safe
circuits |
|
Electrical Characteristics
Test voltage : conductor / conductor
1500 V for 5 min.
conductor
/ screen 1000 V for 1 min.
Conductor
resistance at 20 °C in
d.c. (bare copper conductors
7 strands IEC 60228
class 2)
Stranded |
<
39 Ω /km for size
0.5 sqmm (20 AWG) 7
/ 0.30 mm |
<
24.5 Ω /km for size
0.75 sqmm 7
/ 0.37 mm |
<
18.1 Ω /km for size
1 sqmm
7
/ 0.43 mm |
|
< 13.4 Ω /km for size
1.3 sqmm (16 AWG) 7
/ 0.50 mm
|
<
12.1 Ω /km for size
1.5 sqmm 7
/ 0.53 mm |
<
7.4 Ω /km for size
2.5 sqmm 7
/ 0.67 mm |
Insulation
spark test 6000 V a.c. |
Insulation
resistance at 20 °C PE
> 5000 M Ω / km
PVC
> 100 M Ω / km
XLPE
> 1000 M
Ω / km |
Mutual
capacitance between adjacent
conductor (nF/km at 1000
Hz) |
| Insulation |
Collective
screened cable
(except 1 2 pair) |
Individual
screened cable and
1-2 pair collective screened cable |
| PVC |
100 |
180 |
| PE |
60 |
100 |
| XLPE |
90 |
140 |
Inductance
< 0.9 mH / km |
|
Characteristics
Conductor : Stranded bare copper to IEC
60228 class 2 (7 strand).
Insulation
: Series 3316R : PE (low density polyethylene)
Series
3446R : PVC AF (reduced fire propagation)
Series 6516R and 6016R : XLPE
Series
5516R : PVC
Overall screen (OS) : aluminium
/ polyester tape with stranded tinned
copper drain wire size 0.5 mm 2 (20
AWG)
Inner sheath (armoured cables only)
:
Series
5516R : PVC
:
Series
3446R : PVCAF
:
Series
3316R, 6516R and 6016R : PE
Armour (SWA) : single
layer of galvanized steel wires Ø 0.9
mm, 90% coverage
Outer sheath : Series
3316R, 6516R and 5516R : PVCIR
:
Series
3446R : PVCAFIR
:
Series
6016R : LSZH M1
Operating temperature
: - 20 °C to
+ 80 °C
| Series
N. cores |
Type:
Screened
Screened and armoured |
Flame
retardant
properties |
Other
characteristics |
3316R
2 or 3
3316R 2 or 3
SWA |
PE
/ OS / PVCIR
PE / OS /
PE / SWA / PVCIR |
IEC
60332 1 * |
Oil
and Hydrocarbons
resistant |
3446R
2 or 3
3446R 2 or 3
SWA |
PVCAF
/ OS / PVCAFIR
PVCAF /
OS / PVCAF / SWA / PVCAFIR |
IEC
60332 1
cat. AF BF
CF |
Oil
and Hydrocarbons
resistant |
6516R
2 or 3
6516R 2 or 3
SWA |
XLPE
/ OS / PVCIR
XLPE / OS
/ PE / SWA / PVCIR |
IEC
60332 1 * |
Oil
and Hydrocarbons
resistant |
5516R
2 or 3
5516R 2 or 3
SWA |
PVC
/ OS / PVCIR
PVC / OS /
PVC / SWA / PVCIR |
IEC
60332 1 * |
Oil
and Hydrocarbons
resistant |
6016R
2 or 3
6016R 2 or 3
SWA |
XLPE
/ OS / LSZH M1
XLPE / OS
/ PE / SWA / LSZH M1 |
IEC
60332 1 * |
Halogen
free and low
smoke emission-Oil
and Hydrocarbons resistant |
*
IEC 60332 3 cat.
C F on request |
|
|
 |
Range and Dimensions
Conductor size 0.5 mm 2 (20
AWG)
| |
Screened |
Screened
and armoured |
| Series
Cond.
size (mm
2 ) |
Outer
diameter
(mm)
|
Weight
(kg
/ km)
|
Under
armour
diameter (mm) |
Outer
diameter (mm) |
Weight
(kg
/ km) |
3316R 2 x 0.5 |
5.8 |
44.5 |
5.8 |
10.1 |
19.7 |
3316R
3 x 0.5 |
7.0 |
58.4 |
7.0 |
11.1 |
235.3 |
3446R
2 x 0.5 |
5.8 |
49.4 |
5.8 |
10.0 |
213.8 |
3446R
3 x 0.5 |
6.1 |
54.9 |
6.1 |
10.3 |
225.9 |
6516R
2 x 0.5 |
5.8 |
44.5 |
5.8 |
10.0 |
197.7 |
| 6516R
3 x 0.5 |
6.1 |
50.2 |
6.1 |
10.3 |
209.3 |
| 5516R
2 x 0.5 |
5.8 |
47.0 |
5.8 |
10.0 |
209.4 |
| 5516R
3 x 0.5 |
6.1 |
53.9 |
6.1 |
10.3 |
222.8 |
| 6016R
2 x 0.5 |
5.8 |
45.5 |
5.8 |
10.0 |
199.7 |
| 6016R
3 x 0.5 |
5.8 |
51.3 |
6.1 |
10.3 |
211.4 |
|
Conductor size 1.0 mm 2
| |
Screened |
Screened
and armoured |
|
Series
Cond.
size (mm 2 ) |
Outer
diameter (mm)
|
Weight
(kg / km)
|
Under
armour
diameter (mm) |
Outer
diameter (mm) |
Weight
(kg / km) |
3316R
2 x
1.0
|
6.6
|
60.3 |
6.6 |
10.8 |
230.0 |
3316R
3 x
1.0
|
7.9
|
79.7
|
7.9 |
12.0 |
230.0 |
3446R
2 x
1.0
|
6.6
|
67.1 |
6.6 |
10.8 |
249.8 |
3446R
3 x
1.0
|
7.0
|
76.8 |
7.0 |
11.1 |
267.5 |
6516R
2 x
1.0
|
6.6
|
60.4 |
6.6 |
10.8 |
230.1 |
| 6516R
3 x
1.0 |
7.0 |
70.7 |
7.0 |
11.1 |
247.6 |
| 5516R
2 x
1.0 |
6.6 |
63.7 |
6.6 |
10.8 |
244.1 |
| 5516R
3 x
1.0 |
7.0
|
75.6 |
7.0 |
11.1 |
263.9 |
| 6016R
2 x
1.0 |
6.6 |
61.6 |
6.6 |
10.8 |
232.3 |
| 6016R
3 x
1.0 |
7.0
|
71.9 |
7.0 |
11.1 |
249.8 |
|
Conductor size 1.5 mm 2
| |
Screened |
Screened
and armoured |
|
Series
Cond.
size (mm 2 ) |
Outer
diameter (mm) |
Weight
(kg / km) |
Under
armour
diameter (mm) |
Outer
diameter (mm) |
Weight
(kg / km) |
3316R
2 x 1.0 |
7.4 |
77.3 |
7.4 |
11.6 |
263.4 |
3316R
3 x 1.0 |
8.7 |
103.4 |
8.7 |
13.0 |
320.3 |
3446R
2 x 1.0 |
7.4 |
86.5 |
7.4 |
11.6 |
287.3 |
3446R
3 x 1.0 |
7.9 |
100.6 |
7.9 |
12.0 |
311.0 |
6516R
2 x 1.0 |
7.4 |
77.4 |
7.4 |
11.6 |
263.5 |
| 6516R
3 x 1.0 |
7.9 |
92.3 |
7.9 |
12.0 |
287.0 |
| 5516R
2 x 1.0 |
7.4 |
81.8 |
7.4 |
11.6 |
280.2 |
| 5516R
3 x 1.0 |
7.9 |
99.0 |
7.9 |
12.0 |
306.7 |
| 6016R
2 x 1.0 |
7.4 |
78.7 |
7.4 |
11.6 |
265.8 |
| 6016R
3 x 1.0 |
7.9 |
93.7 |
7.9 |
12.0 |
289.4 |
|
|
 |
|