NYY-J |
| |
|
Power
cable 0.6/1 kV
PVC-insulated,
according to VDE 0271 |
| |
|
|
|

|
 |
Applications |
These power cables insulated with thermoplastic PVC are used in power plants, industrial and switching installations, in secondary distribution networks and for the needs of power supply companies. These cables are preferentially used in outdoor applications, for indoor installation and in cable ducts as well as for outdoor and underwater applications provided mechanical damage is not anticipated.
Characteristic features
Sheath
colour black, resistant to UV radiation.
No
sealing ends are required for installation
in dry rooms.
Installation
Notes
The cables shall be laid and operated such that the characteristics
are not impaired.
The current carrying
capacity for operating conditions
as specified according to VDE 0298
part 2 shall be observed, such as
grouping with other cables, external
sources of heat, specific resistance
to heat from the ground etc.
Installation
on firm and smooth floors of the
ditch, free of stones and embedding
in sand or soil free of stones.
Attention
shall also be paid to tectonic movements,
oscillations, vibration, tensile
forces, bending radius and the temperature
range for installation, as well as
short-circuit currents, especially
with single-core cables.
Protection
against mechanical damage and chemical
effects.
Refer to DIN
VDE 0298 part 1 for additional information.
Durability
Chemical resistance of PVC refer also to the Table of Technical
Guidelines.
|
 |
Cable design
Construction designed according
to DIN VDE 0271 and IEC 502
Conductor
: Cu conductor, plain, single or multiple
wire
Construction of : according to
VDE 0295 Class 1 or 2, and the conductor
IEC 228 Class 1 or 2,
refer also to
the Table of Technical Guidelines
Insulation
: core insulation of PVC, compound
type YI4 according to VDE 0207 part
4
Core identification : single-core
green-yellow, for multiple core according
to VDE 0293
Protective earth conductor : green-yellow
Type of lay-up : concentric lay-up
of cores in layers
Common core : of
filling compound jacket
Sheath : sheath
material of PVC, compound, type YM3
according to VDE 0207 part
Sheath colour
: black * )
* ) with blue sheath for
intrinsically safe installations available
upon request
Note
Current carrying capacity
according to VDE 0298 part 2, refer
also to the Table of Technical Guidelines.
Other
core configurations and special constructions
manufactured upon request.
|
 |
Technical Data
Conductor
resistance at 20 °C
(loop) :
according to VDE 0295 Class 1 or 2, and IEC Class 1 or 2, refer also to the
Table of Technical Guidelines
Temperature max. : + 70 °C in
operation
at the conductor + 160 °C in
the event of a short circuit (max.
5s)
Rated
voltage U o /U : 0.6/1 kV
Test voltage,
AC, 50 Hz : 4 kV
Bending radius
single-core : 15 x cable
diameter
multiple core : 12 x cable
diameter
Temperature range
mobile : + 5 °C
to + 50 °C
fixed : - 30 °C to
+ 70
°C
Max.
permissible tensile : 50 N/ mm 2 x
total conductor force during installation
cross section
Radiation resistance
: 80 Mrad (80 x 10 6 cJ/kg)
Testing according to
DIN VDE 0472 and IEC regulations
Flame
test : test class B according to VDE
0472 part 804 and IEC 332-1
PVC characteristics
: self-extinguishing and flame-retardant
|
 |
Dimensions
| Reference |
Approx.
Outer
Diameter
In mm
|
Copper
Weight
Kg/km
|
Approx.
Cable weight
Kg/km
|
| Part no.
06...
Type
|
No. of conductors
Nominal cross
section mm2
|
| NYY-J |
1x
4 re |
|
|
|
| |
1x 6 re |
10 |
|
|
| |
1x
10 re |
11 |
|
|
| |
1x 16
re |
12 |
|
|
| |
1x
25 rm. |
13 |
|
|
| |
1x 35
rm. |
14 |
|
|
| |
1x
50 rm. |
16 |
|
|
| |
1x 70
rm. |
17 |
|
|
| |
1x
95 rm. |
19 |
|
|
| |
1x120
rm. |
21 |
|
|
| |
1x150
rm. |
23 |
|
|
| |
1x185
rm. |
25 |
|
|
| |
1x240
rm. |
28 |
|
|
| |
1x300 rm. |
30 |
|
|
| |
1x400
rm. |
34 |
|
|
| |
1x500 rm. |
38 |
|
|
| |
|
|
|
|
| NYY-J |
3x 1.5
re |
|
|
|
| |
|
|
|
|
| |
3x 4 re |
|
|
|
| |
|
|
|
|
| |
3x 10
re |
|
|
|
| |
3x 16
re |
|
|
|
| |
|
|
|
|
| |
3x 35
sm. |
|
|
|
| |
3x 50
sm. |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
3x 240 sm. |
53 |
6912 |
8290 |
3 + 1/2 conductor cable 1)
|
|
|
|
| NYY-J |
3x 25
rm/16 re |
|
|
|
| |
3x 35
sm/16 re |
|
|
|
| |
|
|
|
|
| |
3x 70
sm/35 sm. |
|
|
|
| |
3x 95
sm/50 sm. |
|
|
|
| |
|
|
|
|
| |
3x150
sm/70 sm. |
|
|
|
| |
|
|
|
|
| NYY-J |
3x185
sm/95 sm. |
|
|
|
| |
3x240
sm/120 sm. |
|
|
|
| |
3x300
sm/150 sm. |
|
|
|
| |
|
|
|
|
| NYY-J |
4x 1.5
re |
|
|
|
| |
4x 2.5
re |
|
|
|
| |
4x 4 re |
|
|
|
| |
4x 6 re |
|
|
|
| |
4x 10
re |
|
|
|
| |
4x 16
rm. |
|
|
|
| |
4x 25 rm. |
|
|
|
| |
4x 35 sm. |
|
|
|
| |
4x 50 sm. |
|
|
|
| |
4x 70 sm. |
|
|
|
| |
4x 95 sm. |
|
|
|
| |
4x 120
sm. |
|
|
|
| |
4x 150
sm. |
|
|
|
| |
4x
185 sm. |
52 |
|
|
| |
4x 240
sm. |
59 |
9216 |
11000 |
|
 |
1) Only
one conductor of reduced cross section
is permitted for cables with 3 full size
which may be arranged in the outer layer