Elektronenstrahl-Vernetzung, สายเคเบิลอาคาร (Building cable), betaflam fr,cables PVC, Temperature Transmitters | Thermistors, MINERAL INSULATED RTD CABLE, betaflam fr,cables PVC, สายเคเบิลเครือข่าย (Network cable), protect, power and switch, cables in thailand, sattel in thailand,betaflam,Coax Cable Thailand, MI Cable,BETAFLAM,cable,Industrial Computer thailand, references cable site PVC CABLE Wire & Cables Thermocouple cable with a choice of PVC, PTFE PFA & FG insulation, stainless steel over braid and coducter material,niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102 Elektronenstrahl-Vernetzung Tunnel, Tunnelinstallation, BETA Vernetzung Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, BETAflam? FR MI Cable / Multicore Power and Control สายไฟ ทนไฟไหม้ BETAflam? Flexible MI Comms Cables (Screened), BETAflam railway power cables and high-performance cables wide operating temperature range low smoke density STUDER CABLES, Studer, Kabel, Studer-Kabel, studerkabel, studercables schweiz, Studer Services Studer Asia Pacific, BETAflam, BETAtherm, BETAjet, BETArail, ROFLEX, BETAfixss, TRI-DELTA TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, flammwidrig, Funktionserhalt, Sicherheitskabel Spezialkabel, PVC, E 30, E 90, FE 180, FE 0 mittelspannungskabel, niederspannungskabel, netzkabel mittelspannung, niederspannung, kabelsysteme,betaflam fr,cables PVC insulated wiring Electric Heat Tracing Self-Regulating Heat Tracing MI Cable Electric Heat Tracing Snow Melting, Electric Heat Cable Electric Heat Tracing, MI Cable, Tank Heater, Self-Regulating Heating Cable, Mineral Insulated Heat Tracing MI Cable,High Temperature Exposure,High Power Outputs,High Maintain Temperatures,Thermocouple Wire Maintaining Process Fluid Temperatures, Low Watt Density Process Maintain Temperature Applications Buy Thermocouple Wire!,Bare Wire,Thermocouple Insulated Wire, Extension Grade Wire Twisted Shielded Wire Wire with Overbraiding MI Cable Multipair Thermocouple Wire Types,Duplex Insulated Thermocouple Wire,Metal Sheathed Thermocouple Wire,What is thermocouple wire? Thermocouple wire is a cable made from two dissimilar metals for the purpose of measuring temperature, Thermocouple wire is typically used to connect a thermocouple to a sensing device Data Communications and Coax Cable, wire, thermocouple wire,SLE, Insulated thermocouple wire extension grade, AWG, overbraid, overbraided Electronic Component Products that connect protect, power and switch Thermometers | Load Cells | Magnetic Flow Meters Panel Meters | Pressure Gauges | Pressure Transducers,RTD | Signal Conditioners | Strain Gauges | Temperature Controllers Temperature Labels | Temperature Measurement, Temperature Transmitters | Thermistors Thermocouple | Thermocouple Wire MINERAL INSULATED RTD CABLE MINERAL INSULATED THERMOCOUPLE CABLE สายไฟ ทนไฟไหม้ BETAflam? FR MI Cable / Single Core,สายไฟ ทนไฟไหม้ ASIA,Bangkok, Thailand,Singapore, Malaysia,Taiwan, Electricity Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, สาย USB แบบยูนิเวอร์แซล ซีเรียล บัส (Universal serial bus USB cables), Extension Grade Wire, สายเคเบิลเปลือย (Bare cable), Buy Thermocouple Wire!,Bare Wire,Thermocouple Insulated Wire, Thermocouple | Thermocouple Wire, สายไฟฟ้าเป็นฉนวนหรือมีสิ่งปิด (Insulated or covered wire), Elektronenstrahl-Vernetzung, BETAflam® FR MI Cable / Multicore Power and Control, สายเคเบิลอาคาร (Building cable), niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102, สายเคเบิลแกนร่วม (Coaxial cable), BETAflam® FR MI Cable / Single Core, Elektronenstrahl-Vernetzung, ASIA,Bangkok, Thailand,Singapore, Malaysia,Taiwan, Electricity, สายไฟส่วนขยาย (Extension cord), BETAflam railway power cables and high-performance cables, สายเคเบิลเรือดำน้ำ (Submarine cable), Studer Asia Pacific, BETAflam®, BETAtherm, สายเคเบิลอาคาร (Building cable), Wire with Overbraiding, Extension Grade Wire, สายเคเบิลอาคาร (Building cable), MINERAL INSULATED RTD CABLE, STUDER CABLES, สายไฟฟ้าแม่เหล็ก (Magnet wire), Electric Heat Tracing, MI Cable, Tank Heater, Studer Asia Pacific, BETAflam®, BETAtherm, สายไฟฟ้าติดตั้ง (Fixture wire), สายเคเบิลอาคาร (Building cable), สายเคเบิลต่อสาย (Inter connect cable), wide operating temperature range, low smoke density, Temperature Transmitters | Thermistors,
Company Profile
Products
News
Certificate
contact us
 
  
 
  
 

Home  domain names Catalog Request  domain names  Customer Support  email addresses Site References  web hosting   JOBs  web tools Links  help
Personal Domains
Products

   
  Ignition cable 16 kV High-voltage ignition cable 15 kV and 20 kV Cable for fluorescent tubes 4 kV and 7.5 kV
     




Applications

Ignition cable 16 kV, blue

Used mainly in automobile applications or for high fluctuations in the ambient air temperature up to + 180 °C, with inner braid for greater mechanical stability.

High-voltage ignition cable 15 kV and 20 kV, oxbrown-red
Used mainly in automobile applications or for high fluctuations in the ambient air temperature up to + 180 °C.

Cable for fluorescent tubes 4 kV and 7.5 kV, yellow
Used in fluorescent tube lighting systems for high fluctuations in the ambient air temperature up to + 180 °C. The installation must be protected, either in steel conduit or in flexible steel tubing of steel ribbon only, on or beneath plaster.

Characteristic features
•  In the event of fire, no fire support; retention of the insulation and low smoke emission.

Durability
•  The silicone compound is resistant to ozone, oxygen and weathering.
•  Refer also to the Table of Technical Guidelines for the chemical resistance properties of silicone compounds.


Cable design

Ignition cable 16 kV, blue
Conductor : tinned Cu conductor, flexible
Construction of conductor : according to VDE 0295 Class 5 and IEC 228 Class 5
Insulation : of silicone, compound type 2GI1 according to VDE 0207 part 20
Wrapping : glass fibre braid with optimum surface coverage
Sheath : sheath material of silicone, compound type 2GM1 according to VDE 0207 part 21,blue

High-voltage ignition cable 15 kV, and 20 kV oxbrown-red
Conductor : tinned Cu conductor, 19 x 0.25 mm
Insulation : of silicone, compound type 2GI1 according to VDE 0207 part 20, oxbrown-red

Cable for fluorescent tubes 4 kV and 7.5 kV, yellow
Conductor : tinned Cu conductor, flexible
Construction of : according to VDE 0295 Class 5 and IEC conductor 228 Class 5
Insulation : of silicone, compound type 2GI1 according to VDE 0207 part 20, yellow



Technical Data

Ignition cable 16 kV, blue
Rated voltage U o : 16 kV
Test voltage : 20 kV

High-voltage ignition cable 15 kV, and 20 kV oxbrown-red
Test voltage for 5 mm- Ø : 15 kV
for 7 mm- Ø : 20 kV

Cable for fluorescent tubes 4 kV and 7.5 kV, yellow
Rated voltage U o : 4 kV and 7.5 kV respectively
Test voltage AC, 50 Hz             : 2500 V          
Minimum bending radius            : 7.5 x cable diameter
Temperature range
            Mobile : - 25 °C to + 180 °C
            Fixed : -60 °C to + 180 °C
            short period : + 250 °C
Radiation resistance : 20 Mrad (20 x 106 cJ/kg)
Testing: according to DIN VDE 0472 and IEC regulations
            Flame test : test class B according to VDE 0472 part 804 and IEC 332-1 and IEC 332-3
            Insulation retention : according to VDE 0472 part 814 and IEC 331



Dimensions

Reference
Conductor
construction
Approx.
Outer
Diameter
mm
Copper
Weight

Kg/km

Approx.
Cable weight

Kg/km

Part no.
06...
Type
Conductors
cross section
mm2

Ignition cable 16 kV, blue

Ignition cable 16 kV, blue
1.0

32x0.20

8.0

9.6

75

Ignition cable 16 kV, blue
1.5
30x0.25
8.5
14.4
90

High-voltage ignition cable 15 kV, and 20 kV oxbrown-red

High-voltage ignition cable 15 kV, oxbrown-red
1.0

19x0.25

5.0

9.6

58

High-voltage ignition cable 20 kV, oxbrown-red
1.0

19x0.25

7.0

9.6

33

Cable for fluorescent tubes 4 kV and 7.5 kV, yellow
Cable for fluorescent tubes 4 kV
1. 5

30x0.25

6.6

14.4

58

Cable for fluorescent tubes 7.5 kV
1. 5

30x0.25

7.6
14.4

75

           


 
 