ÖPVC-Flat-CY |
PVC-insulated flat flexible cable
Single cores or conductor groups with Cu screen |
| |
|
|
|

|
 |
Applications |
These PVC-insulated flat flexible
cables with copper screen are used
for installation as power and control
cables for cable tracks and carriers,
transport systems, tool machinery,
in particular for hoisting equipment,
lifts, crane and container bridges
and in all circumstances in which the
cable is subjected to severe bending
and continuous movement in one plane
only, and an interference-free transmission
of data and signals must be assured.
These flat flexible cables are suitable
for installation in dry, moist and
wet rooms.
The single-core braided screen consisting
of tinned copper wires prevents mutual
interaction from adjacent circuits,
provides protection against high-frequency
external pulses and ensures an interference-free
transmission.
Characteristic features
The reduced dimension
means that these flat flexible cables
are space-saving compared to round
flexible cables. Considerably smaller
bending radius than for round flexible
cables.
Multiple bundling
of flat flexible cables possible.
A
uniform loop is formed in the axial direction
such that no excess lay-up or twisting
of the cores can occur.
|
 |
Cable design
Construction designed on the
basis of VDE 0281 part 403
Conductor
: plain Cu wires, flexible, according
to VDE 0295 Class 5 and IEC 228 Class
5
Insulation : core insulation of special
PVC compound
Core identification :
colour coded
Protective earth conductor: green-yellow
for 4x4x1 and 6x2.5 only
Core screen
: single-core screen or screened groups
Core configuration : screened cores
or screened groups
Parallel and adjacent
Sheath : sheath
material of special PVC compound
Sheath
colour : black as the preferred colour
|
 |
Technical Data
Conductor resistance at 20 °C
: according to VDE 0295
Class 5 and
IEC 228 Class 5
Temp. at the conductor
max. : + 70 °C
in operation
+
150
°C
in the event of a short circuit
Insulation resistance
at 20 °C
min. : 20 MΩ.km
Rated voltage U o /U
: 300/500 V
Test voltage AC, 50 Hz
: 3000 V
Breakdown voltage min. :
6000 V
Bending radius : 10 x cable
thickness
Temperature range
mobile : - 5 °C
to + 70 °C
fixed : -40 °C
to + 80 °C
Radiation resistance : 80
Mrad (80 x 106 cJ/kg
Testing: according
to DIN VDE 0472, IEC regulations
Flame test : test class B according
to VDE 0472 part 804 and IEC 332-1
PVC characteristics : self-extinguishing
and flame-retardant
|
 |
Dimensions
| Reference |
Approx.
Outer
Diameter
In mm
|
Copper
Weight
Kg/km
|
Approx.
Cable weight
Kg/km
|
| Part no.
06...
Type
|
No. of conductors
Nominal cross
section mm2
|
| ÖPVC-Flat-CY |
|
|
|
|
| |
5x0.5 |
21.0x3.4 |
64 |
95 |
| |
5x4x0.5
* |
37.4x7.2 |
160 |
285 |
| |
8x7x0.5 * |
68.6x11.7 |
480 |
660 |
| |
4x4x1
* |
33.5x11.0 |
310 |
360 |
| |
6x2.5 |
37.4x7.2 |
240 |
380 |
|
 |
Note
ÖPVC-Flat-CY screened in groups
|
| |
 |
| |