Twisted Shielded Wire, betaflam fr,cables PVC, Thermocouple | Thermocouple Wire, สายทองแดง (Copper cable), รอกม้วนสายเคเบิล (Cable reels), MINERAL INSULATED RTD CABLE, PVC CABLE, สายเคเบิลอาคาร (Building cable), cables in thailand, sattel in thailand,betaflam,Coax Cable Thailand, MI Cable,BETAFLAM,cable,Industrial Computer thailand, references cable site PVC CABLE Wire & Cables Thermocouple cable with a choice of PVC, PTFE PFA & FG insulation, stainless steel over braid and coducter material,niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102 Elektronenstrahl-Vernetzung Tunnel, Tunnelinstallation, BETA Vernetzung Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, BETAflam? FR MI Cable / Multicore Power and Control สายไฟ ทนไฟไหม้ BETAflam? Flexible MI Comms Cables (Screened), BETAflam railway power cables and high-performance cables wide operating temperature range low smoke density STUDER CABLES, Studer, Kabel, Studer-Kabel, studerkabel, studercables schweiz, Studer Services Studer Asia Pacific, BETAflam, BETAtherm, BETAjet, BETArail, ROFLEX, BETAfixss, TRI-DELTA TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, flammwidrig, Funktionserhalt, Sicherheitskabel Spezialkabel, PVC, E 30, E 90, FE 180, FE 0 mittelspannungskabel, niederspannungskabel, netzkabel mittelspannung, niederspannung, kabelsysteme,betaflam fr,cables PVC insulated wiring Electric Heat Tracing Self-Regulating Heat Tracing MI Cable Electric Heat Tracing Snow Melting, Electric Heat Cable Electric Heat Tracing, MI Cable, Tank Heater, Self-Regulating Heating Cable, Mineral Insulated Heat Tracing MI Cable,High Temperature Exposure,High Power Outputs,High Maintain Temperatures,Thermocouple Wire Maintaining Process Fluid Temperatures, Low Watt Density Process Maintain Temperature Applications Buy Thermocouple Wire!,Bare Wire,Thermocouple Insulated Wire, Extension Grade Wire Twisted Shielded Wire Wire with Overbraiding MI Cable Multipair Thermocouple Wire Types,Duplex Insulated Thermocouple Wire,Metal Sheathed Thermocouple Wire,What is thermocouple wire? Thermocouple wire is a cable made from two dissimilar metals for the purpose of measuring temperature, Thermocouple wire is typically used to connect a thermocouple to a sensing device Data Communications and Coax Cable, wire, thermocouple wire,SLE, Insulated thermocouple wire extension grade, AWG, overbraid, overbraided Electronic Component Products that connect protect, power and switch Thermometers | Load Cells | Magnetic Flow Meters Panel Meters | Pressure Gauges | Pressure Transducers,RTD | Signal Conditioners | Strain Gauges | Temperature Controllers Temperature Labels | Temperature Measurement, Temperature Transmitters | Thermistors Thermocouple | Thermocouple Wire MINERAL INSULATED RTD CABLE MINERAL INSULATED THERMOCOUPLE CABLE สายไฟ ทนไฟไหม้ BETAflam? FR MI Cable / Single Core,สายไฟ ทนไฟไหม้ ASIA,Bangkok, Thailand,Singapore, Malaysia,Taiwan, Electricity MI Cable, STUDER CABLES, Studer, , สายไฟฟ้าบรอนซ์ (Bronze wire), Thermocouple cable with a choice of PVC, PTFE, สายไฟฟ้าทองแดง-เหล็ก (Copper steel wire), รอกม้วนสายเคเบิล (Cable reels), สายเคเบิลอาคาร (Building cable), Wire with Overbraiding, Multipair, niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102, Extension Grade Wire, cable,Industrial Computer thailand, เครื่องบังเหียนรัดสายไฟบนแผง (Panel wiring harness), Wire with Overbraiding, สาย USB แบบยูนิเวอร์แซล ซีเรียล บัส (Universal serial bus USB cables), สายเคเบิลอาคาร (Building cable), Metal Sheathed Thermocouple Wire,What is thermocouple wire?, สายเคเบิลอาคาร (Building cable), Electronic Component Products that connect, betaflam fr,cables PVC, สายไฟฟ้าเป็นฉนวนหรือมีสิ่งปิด (Insulated or covered wire), สายไฟฟ้ามีสิ่งปิดแต่ไม่เป็นฉนวน (Covered but not insulated wire), schweiz, Studer Services, สายไฟ (Power cord), Thermocouple wire is a cable made from two dissimilar metals for the purpose of measuring temperature., สายเคเบิลอาคาร (Building cable), สายไฟฟ้าใช้ความร้อน (Heating wire), protect, power and switch, สายเคเบิล (Network patch cables), TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, Tunnel, Tunnelinstallation, BETA Vernetzung, Data Communications and Coax Cable, Thermocouple wire is typically used to connect a thermocouple to a sensing device, สายทองแดง (Copper cable),
Company Profile
Products
News
Certificate
contact us
 
  
 
  
 

Home  domain names Catalog Request  domain names  Customer Support  email addresses Site References  web hosting   JOBs  web tools Links  help
Personal Domains
Products

  RE-2X (St)Ymb, Lg,   Instrumentation cable with static screen flame-retardant,
  black and blue
     
   
Page 1 | 2

PV-af Alternative designations :
RE-2X (St)Y
XLPE/OSCR/PVC




Applications

These computer cables with flame-retardant PVC outer sheath and XLPE core insulation are used for optimum data transmission for medium transmission rates up to 200 kbits/s in process control and data processing systems.
Short and different pitch lengths for the pairs guarantee favourable crosstalk attenuation values. Low operating capacitance and attenuation values enable large transmission distances and short pulse times.
The static screen (St) of plastic coated metal foil protects the circuits from external electrical interference for compliance with capacitance unbalance specifications and to assure an exact pulse transmission. These cables are suitable for permanent installation in dry, moist and wet rooms, for outdoor applications and underground installation.

Characteristic features

•  XLPE core insulation guarantees a low capacitance value.
•  Twisted pairs with selected pitch lengths guarantee good crosstalk attenuation values.
•  The black PVC outer sheath is resistant to UV radiation.

Durability

•  The PVC sheath is largely resistant to oils.
•  Chemical resistance of PVC-refer also to the Table of Technical Guidelines.



Cable design

Construction designed on the basis of VDE 0815, VDE 0816
                                                and KEMA K42, K71 and K102
Conductor                              : plain Cu wires, 7-strand
Construction of the conductor: 0.5 mm2 = 7 x 0.3 mm
                                                 1.3 mm2 = 7 x 0.49 mm
Insulation                               : core insulation of XLPE (Cross-linked polyethylene), wall thickness 0.4 mm
According to VDE 0207 part 4
Pair : 2 cores twisted to a pair with short pitch
Pair identification: single colour with imprinted numbers, a-core black, b-core white with imprinted numbers 1/1, 2/2 etc.
Lay-up : concentric lay-up of pairs in layers with optimum pitch
Communications core : XLPE-insulated, orange for multiple pair version included in lay-up
Wrapping : of plastic foil, overlapping
Screen (St) : static screen of plastic coated metal foil, metal side on the inside and 1 Cu drain wire
0.5 mm 2 (7 x 0.3 mm) under the metal foil
Sheath : sheath material of PVC
Sheath colour : black, blue also available(RAL 5015) **)

•  Note
* ) other identification available upon request.

•  Note
**) with blue sheath for intrinsically safe systems available upon request.



Technical Data

Cross section    : 0.5 mm2  1.3 mm2
Conductor resistance max:   39.2 14.2 /km
Insulation resistance min.      5   5 G .km
Operating capacit. at 800 Hz core/core max.    50 60 nF/km
Attenuation at 800 Hz approx   0.88 0.62 dB/km
Inductance     max.   0.70 0.65 mH/km

Crosstalk attenuation

     
       At 60 kHz min.   > 70 dB/km  
       Operating voltage max. U   300 V  
Test voltage AC, 50 Hz      
       core/core   2000 V  
       core/core   2000 V  
Minimum bending radius   7.5 x cable diameter  

 

     
Temperature range    
      Mobile   - 5° C to + 50° C
      Fixed   -40° C to + 80° C
Minimum bending radius   approx. 7.5xcable-Ø
Radiation resistance   80 Mrad (80 x 10 6 cJ/kg)
Testing: according to DIN VDE 0472, IEC,
KEMA regulations
Flame test
 

test class B acc. to VDE 0472
part 804 and IEC 332-1, IEC 332-3C

PVC characteristics
(for outer sheath)
  self-extinguishing and flame-retardant
       
       


Dimensions


PV-af

Sheath-thickness
mm. approx.

Diameter
mm. approx.

Weight
Kg/km, approx.

1x2x0.5

0.7

5.5

34

2x2x0.5

0.8

8.5

90

4x2x0.5

0.9

10.0

108

8x2x0.5
1.1
14.0

166

12x2x0.5
1.2

15.5

226

16x2x0.5
1.2

17.5

289

20x2x0.5
1.2

18.5

342

24x2x0.5
1.2

20.0

397

36x2x0.5
1.2
23.5
569
1x2x0.75

0.8

7.0

44

2x2x0.75

0.9

9.5

80

4x2x0.75

0.9

11.5

147

8x2x0.75

1.2

14.5

213

12x2x0.75

1.2

16.5

278

16x2x0.75

1.3

18.0

370

20x2x0.75

1.3

19.0

400

24x2x0.75

1.4

21.5

516

36x2x0.75

1.4

25.5

744

1x2x1.3

0.9

7.5

63

2x2x1.3

0.9

10.0

132

4x2x1.3

1.1

13.0

202

8x2x1.3

1.2

17.5

325

12x2x1.3

1.4

20.5

467

16x2x1.3

1.4

22.5

604

20x2x1.3

1.4

25.0

770

24x2x1.3

1.4

27.0

839

36x2x1.3

1.7

33.5

1310

1x3x1.3
1.1
8.5
110
2x2x0.5

0.8

10.0

124

4x2x0.5

0.9

10.5

134

8x2x0.5

1.1

14.0

210

12x2x0.5

1.2

17.0

300

16x2x0.5

1.2

20.0

389

20x2x0.5

1.3

21.5

470

24x2x0.5

1.3

23.0

539

36x2x0.5
1.5
25.5
790
2x2x0.75

0.9

10.5

137

4x2x0.75

0.9

12.5

187

8x2x0.75

1.1

15.0

248

12x2x0.75

1.2

18.0

355

16x2x0.75

1.3

18.5

370

20x2x0.75

1.3

22.5

558

24x2x0.75

1.3

25.5

657

36x2x0.75

1.6
30.5
951

2x2x1.3

0.9

11.0

167

4x2x1.3

1.1

13.5

236

8x2x1.3

1.2

18.0

372

12x2x1.3

1.5

22.0

551

16x2x1.3

1.5

23.5

706

20x2x1.3

1.5

26.0

870

24x2x1.3

1.7

27.0

1023

36x2x1.3

1.7

34.0

1543

6x3x1.3

1.2

18.0

334

12x3x1.3
1.5
24.5

572



Electrical characteristics Twenkacom (at 20 ° C)

0.5

0.75

1.3

mm2 
Conduction resistance

< 36.8

< 24.6

< 14.2

/km
Capacitance of 'af'
50
55
60
nF/km
Capacitance of 2af'
70
80
100
nF/km
Induction at 1 kHz
0.7
0.65
0.65
mH/km
Attenuation at kHz of af'
0.9
0.8
0.6
dB/km
Attenuation at 1 kHz of 2af'
1.1
1.0
0.8
dB/km
Speed loss factor
af
0.56
0.56
0.53
 
2af
0.48
0.46
0.41
 
Crosstalk attenuation at 1 MHz of af'  
< 70
 
dB/km
Crosstalk attenuation at 1 MHz of 2af'  
< 85
 
dB/km
Insulation resistance  
> 5
 
G .km
Operating voltage  
250
 
V
Test voltage  
2000
 
V



FIDLD OF APPLICATION

Twenkacom signalling
Control
interfacing (RS232, RS422, RS423, V24, V28 etc) (*)
data-networks(*) < 1 Mbs.
video signals etc.
(*) depening on the distance

 
 
Page 1 | 2