SiHF-GLP-O / SiHF-GLP-J |
Silicone flexible multicore cable with armour, steel wire braid |
| |
|
|
| |
|
|
|

|
 |
Applications |
These flexible armoured cables with
galvanised steel wire braid as additional
protection against mechanical load
are used as connecting cables for equipment
where high temperatures can arise and
for ambient aie temperatures between
- 60 °C
and + 180 °C.
These cables can be subjected to temperatures
up to + 25 0 °C
for short periods. These cables are used in all areas of
high mechanical load where high and low
temperatures can have a direct effect,
e.g. in ship building, in iron and steel
works, in smelting plants, power plants,
foundries, coking plants, glass and ceramic
works, cement works, for high-power lighting
fixtures and spotlights, solarium and
sauna installations .
Characteristic features
Additional
protection against mechanical loads.
Temperature-resistant
from - 60 °C to + 180 °C, for short
periods to + 25 0 °C, flexible at
low temperatures down to - 25 °C in continuous operation.
These
cables are approved to supply temperature
class H up to 180 °C.
In
the event of fire, no fire support;
retention of the insulation and low
smoke emission.
Durability
The silicone compound is resistant to ozone, oxygen and weathering.
Refer
also to the Table of Technical Guidelines for other
chemical resistance properties of
silicone compounds.
|
 |
Cable design
Construction designed on the
basis of VDE 0250 part 1 and part 816
Conductor : tinned Cu wires, flexible
Construction of : according to VDE
0295 Class 5 and conductor IEC 228
Class 5
Insulation : core insulation
of silicone rubber, compound type 2GI1
according to VDE 0207 part 20
Core
Identification: colour coded or black
with imprinted
numbers according to
VDE 0293
Protective earth : without
green-yellow protective earth
conductor
conductor for 2 cores, with green-yellow
protective earth conductor for 3 or
more cores
Type of lay-up : concentric
lay-up of cores in layers
Sheath :
sheath material of silicone rubber,
compound type 2GM1 according to VDE
0207 part 21, oxbrown-red colour
Wrapping
: of glass fibre tape as protective
wrapping
Braid (P) : of galvanised
steel wires of optimum coverage
Note
Other core configurations, cross
sections and special notch-resistant
cable constructions, or resistant
to temperatures up to + 250 °C
for continuous operation, low-voltage
cables for halogen lamps and SiY
versions
|
 |
Technical Data
Conductor resistance at 20 °C : according
to VDE 0295 Class 5 and IEC 228 Class
5, refer also to the Table of Technical
Guidelines
Insulation resistance min.
: 20 M. Ω .km at 20 °C
Temp. At the
conductor max. : + 180 °C in operation
max.
: + 200 °C in the event of a short
circuit
Rated voltage Uo /U : 300/500
V
Test voltage AC, 50 Hz : 2000 V
Breakdown
voltage min. : 20 kV/mm at 20 °C
Minimum
bending radius : 7.5 x cable diameter
Temperature range
Mobile : - 25 °C
to + 180 °C
Fixed : -60 °C to
+ 180
°C
Radiation resistance : 20 Mrad
(20 x 106 cJ/kg)
Testing: according
to DIN VDE 0472 and IEC regulations
Flame test : test class B and test
class C
according to VDE 0472 part 804 IEC
332-1 and IEC 332-3
Insulation retention
: according to VDE 0472 part 814 and
IEC 331
|
 |
Dimensions
| Reference |
Approx.
Outer
Diameter
In mm
|
Copper
Weight
Kg/km
|
Approx.
Cable weight
Kg/km
|
| Part no.
06...
Type
|
No. of conductors
Nominal cross
section mm2
|
| SiHF-GLP-O |
2x0.75
|
|
|
|
| SiHF-GLP-J |
3x0.5 |
7.8 |
|
|
| |
4x0.5 |
8.6 |
|
|
| |
5x0.5 |
9.6 |
|
|
| |
6x0.5 |
10.2 |
|
|
| |
7x0.5 |
10.2 |
|
|
| |
|
|
|
|
| SiHF-GLP-O |
2x1 |
8.0 |
|
98 |
| SiHF-GLP-J |
3x1 |
8.6 |
|
122 |
| |
4x1 |
9.2 |
|
142 |
| |
5x1 |
10.2 |
|
167 |
| |
6x1 |
10.8 |
|
188 |
| |
|
10.8 |
|
198 |
| |
|
|
|
|
| SiHF-GLP-O |
2x1.5 |
8.9 |
|
127 |
| SiHF-GLP-J |
3x1.5 |
9.2 |
|
145 |
| |
4x1.5 |
10.1 |
|
173 |
| |
5x1.5 |
10.8 |
|
203 |
| |
6x1.5 |
11.9 |
|
242 |
| |
|
11.9 |
|
261 |
| |
|
13.0 |
|
312 |
| |
|
14.3 |
|
380 |
| |
12x1.5 |
15.2 |
|
420 |
| |
|
16.2 |
|
446 |
| |
16x1.5 |
17.8 |
|
540 |
| |
|
18.5 |
|
630 |
| |
20x1.5 |
19.0 |
|
695 |
| |
24x1.5 |
21.3 |
|
822 |
| |
|
|
|
|
| SiHF-GLP-O |
2x2.5 |
10.6 |
|
190 |
| SiHF-GLP-J |
3x2.5 |
11.1 |
|
204 |
| |
|
12.1 |
|
280 |
| |
|
13.2 |
|
323 |
| |
|
14.2 |
|
356 |
| |
|
14.2 |
|
380 |
| |
|
18.8 |
|
620 |
| |
|
|
|
|
| SiHF-GLP-O |
2x4 |
12.1 |
|
270 |
| SiHF-GLP-J |
3x4 |
12.8 |
|
310 |
| |
4x4 |
14.2 |
|
382 |
| |
|
15.7 |
|
458 |
| |
|
16.9 |
|
590 |
| |
7x4 |
16.9 |
|
630 |
| |
|
|
|
|
| SiHF-GLP-O |
2x6 |
|
|
360 |
| SiHF-GLP-J |
3x6 |
14.4 |
|
430 |
| |
4x6 |
15.5 |
|
540 |
| |
|
17.6 |
|
650 |
| |
6x6 |
19.0 |
|
740 |
| |
7x6 |
19.0 |
|
820 |
| |
|
|
|
|
| SiHF-GLP-J |
4x10 |
21.0 |
384.0 |
900 |
| |
|
|
|
|
| SiHF-GLP-J |
4x16 |
23.5 |
616.0 |
1210 |
| |
|
|
|
|
| SiHF-GLP-J |
4x25 |
29.4 |
960.0 |
1770 |
| |
|
|
|
|
|
 |
Note
Other core configurations, cross sections or resistant to temperatures up to 250 °C -GLP manufactured upon request.
|
| |
 |
| |