SiHF-O / SiHF-J |
Silicone
flexible multicore cable |
| |
|
temperature-resistant |
| |
|
|
|

|
 |
Applications |
These silicone-insulated multicore
cables, resistant to high and low temperatures,
are used as mobile connecting cables
for equipment where high temperatures
can arise as well as for ambient air
temperatures between -60 °C and +
180°C. These cables can also withstand
temperatures up to +250°C for short
periods.
These cables are used in all areas
of low mechanical load where high and
low temperatures can have a direct
effect, i.g. in ship building, in iron
and steel works, in smelting plants,
power plants, foundries, coking plants,
glass and ceramic works, cement works,
for high-power lighting fixtures and
spotlights, solarium and sauna installations.
Characteristic features
Temperature-resistant
from - 60 °C to + 180 °C, for short
periods to + 250 °C, flexible at
low temperatures down to - 25 °C in continuous operation.
These
cables are approved to supply temperature
class H up to 180 °C.
In
the event of fire, no fire support;
retention of the insulation and low
smoke emission.
Durability
The silicone compound is resistant to ozone, oxygen and weathering.
Resistant
to transmission oil, acetone, aniline, boric acid,
brake fluids, methanol, engine oil,
sulphur dioxide, tartaric and citric
acid, sea water as well as vegetable
and animal fats.
Refer
also to the Table of Technical Guidelines
for other chemical resistance properties
of silicone compounds.
|
 |
Cable design
Construction designed on the
basis of VDE 0250 part 1 and part 816
Conductor : tinned Cu wires, flexible
Construction of conductor: according
to VDE 0295 Class 5 and IEC 228 Class
5
Insulation : core insulation of silicone
rubber, compound type 2GI1 according
to VDE 0207 part 20
Core : colour coded
or black with imprinted Identification
numbers according to VDE 0293
Protective
earth conductor: without green-yellow
protective earth conductor for 2 cores,
with green-yellow protective earth
conductor for 3 or more cores
Type
of lay-up : concentric lay-up of cores
in layers
Sheath : sheath material
of silicone rubber compound type 2GM1
according to VDE 0207 part 21
Sheath
colour : oxbrown-red as the standard
colour
Note
Other core configurations, cross sections
and special notch-resistant cable
constructions, or resistant to temperatures
up to + 250 °C for continuous operation,
low-voltage cables for halogen lamps
and SiY versions
|
 |
Technical Data
Conductor resistance at 20°C : according to VDE 0295 Class 5 and IEC 228
Class 5, refer also to the Table of Technical Guidelines
Insulation resistance
min. at 20 °C: 20 MΩ .km
Temp. At the conductor max. : + 180 °C in operation
max.
: + 200 °C in
the event of a short circuit
Rated voltage Uo /U : 300/500 V
Test voltage AC, 50 Hz : 2000 V
Breakdown voltage min. : 20 kV/mm at 20 °C
Minimum bending radius : 7.5 x
cable diameter
Temperature range
Mobile : - 25 °C to
+ 180 °C
Fixed : -60 °C to
+ 180 °C
Radiation resistance : 20 Mrad (20 x 106 cJ/kg)
Testing: according to DIN
VDE 0472 and IEC regulations
Flame test : test class B and test class C
according to VDE 0472
part 804 IEC 332-1 and
IEC 332-3 espectively
Insulation retention : according to VDE 0472 part 814 and IEC 331
|
 |
Dimensions
| Reference |
Approx.
Outer
Diameter
In mm
|
Copper
Weight
Kg/km
|
Approx.
Cable weight
Kg/km
|
| Part no.
06...
Type
|
No. of conductors
Nominal cross
section mm2
|
| SiHF-O |
2x0.75
|
|
|
|
| SiHF-J |
3x0.5 |
|
|
|
| |
4x0.5 |
|
|
|
| |
5x0.5 |
|
|
|
| |
6x0.5 |
|
|
|
| |
7x0.5 |
|
|
|
| |
|
|
|
|
| SiHF-O |
2x1 |
|
|
|
| SiHF-J |
3x1 |
|
|
|
| |
4x1 |
|
|
|
| |
5x1 |
|
|
|
| |
6x1 |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| SiHF-O |
2x1.5 |
|
|
|
| SiHF-J |
3x1.5 |
|
|
|
| |
4x1.5 |
|
|
|
| |
5x1.5 |
|
|
|
| |
6x1.5 |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
12x1.5 |
|
|
|
| |
|
|
|
|
| |
16x1.5 |
|
|
|
| |
|
|
|
|
| |
20x1.5 |
|
|
|
| |
24x1.5 |
|
|
|
| |
|
|
|
|
| SiHF-O |
2x2.5 |
|
|
|
| SiHF-J |
3x2.5 |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
313 |
| |
|
17.5 |
|
595 |
| |
|
|
|
|
| SiHF-O |
2x4 |
|
|
|
| SiHF-J |
3x4 |
|
|
|
| |
4x4 |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
7x4 |
|
|
|
| |
|
|
|
|
| SiHF-O |
2x6 |
|
|
|
| SiHF-J |
3x6 |
|
|
|
| |
4x6 |
|
|
|
| |
|
|
|
|
| |
6x6 |
|
|
|
| |
7x6 |
|
|
|
| |
|
|
|
|
| SiHF-O |
2x10 |
|
|
|
| SiHF-J |
3x10 |
|
|
|
| |
4x10 |
|
|
|
| |
5x10 |
|
|
|
| |
|
|
|
|
| SiHF-O |
|
|
|
|
| SiHF-J |
3x16 |
|
|
|
| |
4x16 |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| SiHF-O |
2x25 |
|
|
|
| SiHF-J |
3x25 |
|
|
|
| |
4x25 |
|
|
|
| |
|
|
|
|
| SiHF-O |
2x35 |
|
|
|
| SiHF-J |
3x35 |
|
|
|
| |
4x35 |
31.2 |
1344.0 |
2080 |
| |
|
|
|
|
|
 |
Note
Other core configurations,
cross sections and special notch-resistant
cable constructions, or resistant to
temperatures up to 250 °C for
continuous operation, low-voltage cables
for halogen lamps and SiY versions manufactured
upon request.
|
| |
 |
| |