SiD, SiD/GL, SiF, SiF/GL, SiFF, SiFv, SiZ |
| |
Silicone-insulated
flexible single-cores |
| |
|
|
|

|
 |
Applications |
These silicone-insulated single-core cables, resistant to high and low temperatures, are used in all areas where high and low temperatures can have a direct effect, e.g. in all types of heating equipment, in high-power lighting fixtures, spotlights, transformer factories, foundries, iron and steel works, smelting plants, industrial furnace construction, ship building, refrigeration plant construction, driving mechanism construction, coking plants, special vehicles as well as in the chemical and ceramics industry.
Characteristic features
Temperature-resistant
from -60 °C to + 180°C, for short
periods to + 250°C.
Approved
for temperature class H up to + 180°C.
In the event of fire,
no fire support ; retention of the
insulation and low smoke emission.
Durability
The silicone compound
is resistant to ozone, oxygen and
weathering.
Refer also to
the Table of Technical Guidelines for
other chemical resistance properties
of silicone compounds.
|
 |
Cable design
Construction designed on the
basis of VDE 0250 part 1 and VDE 0282
part 601
Conductor : tinned Cu conductor,
solid or flexible according to VDE
0295
Insulation/jacket : of silicone
rubber, compound type 2GI1
according
to VDE 0207 part 20
Core identification
: colour coded, as well as green-yellow
Type
Sid : tinned
Cu conductor, solid, insulation of
silicone compound
Type SiD/GL :
as type SiD plus additional glass fibre
braid
Type SiF : tinned
Cu conductor, flexible, insulation
of silicone compound
Type SiF/GL :
as type SiF plus additional glass fibre
braid
Type SiFF :
as type SiF except Cu wire strands,
extra fine strands
Type SiFv :
SiF cores, two cores twisted together
Type
SiZ : twin cores 2 cores parallel
and adjacent, joined and can be separated
|
 |
Technical Data
Conductor resistance at
20 ? C : according to VDE 0295 and
IEC 228,
refer
also to the Table of Technical Guidelines
Temp. At the conductor max. : + 180
° C in operation
max.
: + 200 ° C in the event of a short
circuit
Rated voltage U ? /U : 300/500 V
Test voltage AC, 50 Hz
up to 1 mm 2 : 1500
V
> 1 mm 2 : 2000
V
Minimum bending radius : 7.5 x cable diameter
Temperature range : - 60 ° C to
+ 180° C
Radiation resistance : 20 Mrad (20
x 106 cJ/kg)
Testing: according to
DIN VDE 0472 and IEC regulations
Flame test : test
class B and test class C according to VDE 0472 part 804, and IEC 332-3
Insulation
retention : according to VDE 0472 Part 814 and IEC 331
|
 |
Dimensions
| Reference |
Conductor
construction
No.of
wires
x wire Ø |
Approx.
Outer
Diameter
In mm
|
Copper
Weight
Kg/km
|
Approx.
Cable weight
Kg/km
|
| Part no.
06...
Type
|
No. of conductors
Nominal cross
section mm2
|
| SiD,
colour coded * minimum
ordering quantity 1000 m
|
| |
0.2 |
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
1 |
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
6 |
1x2.77 |
4.4 |
58.0 |
64.5 |
SiD/GL
* minimum ordering
quantity 500 m to 1000 m,
depending on dimensions |
| |
0.5 |
|
|
|
|
| |
|
|
|
|
|
| |
1 |
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
6 |
1x2.77 |
4.9 |
58.0 |
70.3 |
| SiF,
colore coded |
| |
|
14x0.15 |
|
|
|
| |
|
16x0.2 |
|
|
|
| |
0.75 |
|
|
|
|
| |
1 |
32x0.2 |
|
9.6 |
|
| |
|
30x0.25 |
|
|
|
| |
|
50x0.25 |
|
|
|
| |
4 |
56x0.3 |
|
|
|
| |
|
84x0.3 |
|
|
|
| |
10 |
|
|
|
|
| |
16 |
128x0.4 |
8.4 |
|
|
| |
25 |
200x0.4 |
10.3 |
|
|
| |
35 |
280x0.4 |
11.6 |
|
|
| |
50 |
400x0.4 |
13.9 |
|
|
| |
70 |
560x0.4 |
16.0 |
|
|
| |
95 |
485x0.5 |
18.4 |
|
|
| |
120 |
614x0.5 |
20.0 |
|
|
| |
150 |
765x0.5 |
22.6 |
|
|
| |
185 |
942x0.5 |
24.9 |
1776.0 |
1915.0 |
| SiF/GL
* minimum ordering
quantity 500 m to 1000 m, depending
on dimensions
|
| |
0.25 |
14x0.15 |
|
|
|
| |
|
16x0.2 |
|
|
|
| |
|
24x0.2 |
|
|
|
| |
1 |
32x0.2 |
|
|
|
| |
|
30x0.25 |
|
|
|
| |
|
50x0.25 |
|
|
|
| |
|
56x0.3 |
|
|
|
| |
|
84x0.3 |
|
|
|
| |
|
80x0.4 |
|
|
|
| |
|
128x0.4 |
|
|
|
| |
|
200x0.4 |
|
|
|
| |
35 |
|
|
|
|
| |
50 |
400x0.4 |
14.4 |
480.0 |
578.0 |
| SiFF,
colore coded
|
| |
|
65x0.07 |
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
266x0.07 |
|
|
|
| |
|
392x0.07 |
|
|
|
| |
|
|
|
|
|
| |
|
1041x0.07 |
|
|
|
| |
|
1561x0.07 |
|
|
|
| |
10.0 |
2601x0.07 |
7.6 |
96.0 |
119.7 |
| SiFv,
* minimum ordering
quantity 1000 m of each |
| |
2x0.25 |
14x0.15 |
|
|
|
| |
2x0.5 |
16x0.2 |
|
|
|
| |
2x0.75 |
24x0.2 |
|
|
|
| |
2x1 |
32x0.2 |
|
|
|
| |
2x1.5 |
30x0.25 |
|
|
|
| |
2x2.5 |
50x0.25 |
|
|
|
| |
2x4 |
56x0.3 |
|
|
|
| |
2x6 |
84x0.3 |
10.4 |
116.0 |
146.1 |
| SiZ,
twin cable * minimum
ordering quantity 1000 m
|
| |
2x0.5 |
28x0.15 |
|
|
|
| |
|
42x0.15 |
2.3x4.6 |
14.4 |
21.5 |
|
 |
Note
Other cross sections, colour
codes, cables approved to specifications
of other countries as well as FRNC versions
can be supplied upon request.
|
| |
 |
| |