Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, Studer Asia Pacific, BETAflam®, BETAtherm, Electric Heat Tracing, สายเคเบิลเปลือย (Bare cable), สายไฟ ทนไฟไหม้,สายไฟ ทนไฟไหม้ protect, power and switch, สายเคเบิลเป็นฉนวนหรือมีสิ่งปิด (Insulated or covered cable), สายเคเบิลสัญญาณ (Signal cable), cables in thailand, sattel in thailand,betaflam,Coax Cable Thailand, MI Cable,BETAFLAM,cable,Industrial Computer thailand, references cable site PVC CABLE Wire & Cables Thermocouple cable with a choice of PVC, PTFE PFA & FG insulation, stainless steel over braid and coducter material,niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102 Elektronenstrahl-Vernetzung Tunnel, Tunnelinstallation, BETA Vernetzung Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, BETAflam? FR MI Cable / Multicore Power and Control สายไฟ ทนไฟไหม้ BETAflam? Flexible MI Comms Cables (Screened), BETAflam railway power cables and high-performance cables wide operating temperature range low smoke density STUDER CABLES, Studer, Kabel, Studer-Kabel, studerkabel, studercables schweiz, Studer Services Studer Asia Pacific, BETAflam, BETAtherm, BETAjet, BETArail, ROFLEX, BETAfixss, TRI-DELTA TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, flammwidrig, Funktionserhalt, Sicherheitskabel Spezialkabel, PVC, E 30, E 90, FE 180, FE 0 mittelspannungskabel, niederspannungskabel, netzkabel mittelspannung, niederspannung, kabelsysteme,betaflam fr,cables PVC insulated wiring Electric Heat Tracing Self-Regulating Heat Tracing MI Cable Electric Heat Tracing Snow Melting, Electric Heat Cable Electric Heat Tracing, MI Cable, Tank Heater, Self-Regulating Heating Cable, Mineral Insulated Heat Tracing MI Cable,High Temperature Exposure,High Power Outputs,High Maintain Temperatures,Thermocouple Wire Maintaining Process Fluid Temperatures, Low Watt Density Process Maintain Temperature Applications Buy Thermocouple Wire!,Bare Wire,Thermocouple Insulated Wire, Extension Grade Wire Twisted Shielded Wire Wire with Overbraiding MI Cable Multipair Thermocouple Wire Types,Duplex Insulated Thermocouple Wire,Metal Sheathed Thermocouple Wire,What is thermocouple wire? Thermocouple wire is a cable made from two dissimilar metals for the purpose of measuring temperature, Thermocouple wire is typically used to connect a thermocouple to a sensing device Data Communications and Coax Cable, wire, thermocouple wire,SLE, Insulated thermocouple wire extension grade, AWG, overbraid, overbraided Electronic Component Products that connect protect, power and switch Thermometers | Load Cells | Magnetic Flow Meters Panel Meters | Pressure Gauges | Pressure Transducers,RTD | Signal Conditioners | Strain Gauges | Temperature Controllers Temperature Labels | Temperature Measurement, Temperature Transmitters | Thermistors Thermocouple | Thermocouple Wire MINERAL INSULATED RTD CABLE MINERAL INSULATED THERMOCOUPLE CABLE สายไฟ ทนไฟไหม้ BETAflam? FR MI Cable / Single Core,สายไฟ ทนไฟไหม้ ASIA,Bangkok, Thailand,Singapore, Malaysia,Taiwan, Electricity BETAflam® Flexible MI Comms Cables (Screened), Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, Wire with Overbraiding, สายเคเบิลอาคาร (Building cable), Twisted Shielded Wire, สายเคเบิลเป็นฉนวนหรือมีสิ่งปิด (Insulated or covered cable), สายไฟส่วนขยาย (Extension cord), MI Cable,High Temperature Exposure,High Power Outputs, BETAflam railway power cables and high-performance cables, Coax Cable Thailand, MI Cable,BETAFLAM®, Tunnel, Tunnelinstallation, BETA Vernetzung, สายเคเบิลอาคาร (Building cable), สายไฟฟ้าใช้ความร้อน (Heating wire), MI Cable,High Temperature Exposure,High Power Outputs, สายไฟฟ้าติดตั้ง (Fixture wire), สายเคเบิลอาคาร (Building cable), wide operating temperature range, สายเคเบิลอาคาร (Building cable), TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, Studer Asia Pacific, BETAflam®, BETAtherm, Multipair, สายไฟฟ้าติดตั้ง (Fixture wire), สายเคเบิลอาคาร (Building cable), สายเคเบิลอาคาร (Building cable), low smoke density, เครื่องบังเหียนรัดสายไฟบนแผง (Panel wiring harness), MI Cable,High Temperature Exposure,High Power Outputs, Thermocouple wire is a cable made from two dissimilar metals for the purpose of measuring temperature., สายไฟฟ้าแม่เหล็ก (Magnet wire), wide operating temperature range, สายทองแดง (Copper cable), Wire with Overbraiding, Kabel, Studer-Kabel, studerkabel, studercables, สายเคเบิลเปลือย (Bare cable),
Company Profile
Products
News
Certificate
contact us
 
  
 
  
 

Home  domain names Catalog Request  domain names  Customer Support  email addresses Site References  web hosting   JOBs  web tools Links  help
Personal Domains
Products

  ÖPVC-BLUE-FCY for intrinsically safe systems, with Cu screen Protection class i according to VDE 0165, blue sheath
     
     




Applications

These screened PVC-insulated control cables with blue outer sheath are exclusively used for intrinsically safe systems in instrumentation and control engineering as pulse and data transmission cables as well as connecting cables for public address and two-way intercom systems where high-frequency interference can occur. The overall braided screen, consisting of tinned copper wires with a visible coverage of approx. 85%, provides protection against external pulses and assures an interference-free transmission. These cables with special identification meet the requirements of VDE 0165 Section 6.1.3.2.3 in protection class i and are only used for intrinsically safe electric circuits.
In protection class i , the power in the electric circuit id low such that no igniting sparks, arcs or higher temperatures can occur. These cables are not suitable for underground installation.

Notes
In intrinsically safe electric circuits, only insulated cables may be used with a test voltage of conductor to conductor and conductor to earth of minimum 500 V AC.
These cables and wires designated blue may not be used for other applications.
For reasons of safety and functionality, intrinsically safe electric circuits must be earthed, if required. This earthing may only be made at one position by connection with the equipotential bonding, refer also to VDE 0165 Section 6.1.3.3
When installing systems with intrinsically safe electric circuits, it shall be observed that outside electrical or magnetic fields do not impair the intrinsic safety, which can be realised by the use of screened and/or twisted cables or by maintaining a sufficiently large distance in the spacing.

Note
Other cross sections and core configurations manufactured upon request.



Cable design

Construction designed on the basis of DIN VDE 0245, 0250 and 0281
Conductor :plain Cu wires, flexible
Construction :according to VDE 0295 Class 5
of conductor and IEC 228 Class 5, refer also to the
Table of Technical Guidelines
Insulation : core insulation of special PVC Compound
Core identi- : black with sequential numbering imprint in
fication white according to VDE 0293, yet without
green-yellow protective earth conductor
Type of lay-up :Concentric lay-up of cores in layers of
optimum pitch
Wrapping*) : plastic foil, overlapping
Screen : braid of tinned copper wires, visible
Coverage approx. 85%
Sheath : sheath material of special PVC compound
Sheath colour : sky blue, RAL 5015

*) Available upon request :
Cable with inner sheath : ?PVC-BLUE-YCY



Technical Data


Conductor resistance at 20° C :according to VDE 0295
Class 5 and IEC 228
Class 5 for multistranded
conductors,refer also to
the Table of Technical
Guidelines.
Temperat. at the core max. :+ 70° C in operation
Insulation resistance min. : 20 M Ω .km
Operating voltage max : 500 V
Test voltage AC,50 Hz
core/core :3000v
core/screen : 1200 V
Operating capacitance
core/core approx. : 135 nF/km
core/screen approx. : 185 nF/km
Inductance approx : 0.65 mH/km
Minimum binding radius
up to 12 mm diameter : 10 x cable diameter
> 12 mm diameter : 15 x cable diameter
Temperature range
Mobile : - 5° C to + 70° C
Fixed : -40° C to + 80° C
Radiation resistance : 80 Mrad (80x106 cJ/kg)
Testing: according to DIN VDE 0472 and IEC regulations
Flame test : test class B according to VDE 0472 part 804 and IEC 332-1
PVC characteristics : self-extinguishing and flame-retardant



Dimensions


Reference
Approx.
Outer
Diameter
In mm
Copper
Weight

Kg/km

Approx.
Cable weight

Kg/km

Part no.
02...
Type
No. of conductors
Nominal cross
section mm2
ÖPVC-BLUE-FCY
2x0.75

7.4

46.0

92

 
3x0.75

7.9

58.0

102

 
4x0.75

8.8

65.0

118

 
5x0.75

9.0

80.0

133

 

7x0.75

10.5

102.2

190

 
10x0.75

12.5

156.0

279

 
12x0.75

13.0

177.0

304

 
18x0.75

14.7

243.0

374

 
25x0.75

17.7

316.0

504

 
30x0.75

19.4

402.0

634

 

34x0.75

20.6

466.0

686

 

ÖPVC-BLUE-FCY
2x1

8.2

57.0

113

 
3x1

8.5

76.0

130

 
4x1

9.5

97.0

148

 
5x1

10.2

130.0

172

 
7x1

11.6

160.0
221
 
ÖPVC-BLUE-FCY
12x1

14.5

188.0

362

 
18x1

17.4

286.0

506

 

25x1

21.3

396.0

672

 
34x1

23.0

510.0

741

 
ÖPVC-BLUE-FCY
2x1.5

9.3

77.0

140

 
3x1.5

9.6

93.0

162

 
4x1.5

9.9

127.0

178

 
5x1.5

10.6

144.0

211

 
7x1.5

13.3

194.0

310

 
12x1.5

16.0

295.0

454

 
18x1.5

19.6

385.0

628

 
25x1.5
22.6
580.0

794

 
34x1.5
25.9
732.0
1142
         




Note
Other cross sections and core configurations manufactured upon request.
 
 