BETAjet, BETArail, ROFLEX, BETAfixss, TRI-DELTA, Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, Extension Grade Wire, สายไฟส่วนขยาย (Extension cord), สายไฟฟ้าบรอนซ์ (Bronze wire), Thermocouple Wire Types,Duplex Insulated Thermocouple Wire, สาย USB แบบยูนิเวอร์แซล ซีเรียล บัส (Universal serial bus USB cables), สายไฟฟ้าทองแดง-เหล็ก (Copper steel wire), cables in thailand, sattel in thailand,betaflam,Coax Cable Thailand, MI Cable,BETAFLAM,cable,Industrial Computer thailand, references cable site PVC CABLE Wire & Cables Thermocouple cable with a choice of PVC, PTFE PFA & FG insulation, stainless steel over braid and coducter material,niken, 10 kV, 20 kV, 30 kV, DIN 5510, DIN 4102 Elektronenstrahl-Vernetzung Tunnel, Tunnelinstallation, BETA Vernetzung Tragsysteme, 400 Hz Systeme, industrie, infrastruktur, BETAflam? FR MI Cable / Multicore Power and Control สายไฟ ทนไฟไหม้ BETAflam? Flexible MI Comms Cables (Screened), BETAflam railway power cables and high-performance cables wide operating temperature range low smoke density STUDER CABLES, Studer, Kabel, Studer-Kabel, studerkabel, studercables schweiz, Studer Services Studer Asia Pacific, BETAflam, BETAtherm, BETAjet, BETArail, ROFLEX, BETAfixss, TRI-DELTA TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, flammwidrig, Funktionserhalt, Sicherheitskabel Spezialkabel, PVC, E 30, E 90, FE 180, FE 0 mittelspannungskabel, niederspannungskabel, netzkabel mittelspannung, niederspannung, kabelsysteme,betaflam fr,cables PVC insulated wiring Electric Heat Tracing Self-Regulating Heat Tracing MI Cable Electric Heat Tracing Snow Melting, Electric Heat Cable Electric Heat Tracing, MI Cable, Tank Heater, Self-Regulating Heating Cable, Mineral Insulated Heat Tracing MI Cable,High Temperature Exposure,High Power Outputs,High Maintain Temperatures,Thermocouple Wire Maintaining Process Fluid Temperatures, Low Watt Density Process Maintain Temperature Applications Buy Thermocouple Wire!,Bare Wire,Thermocouple Insulated Wire, Extension Grade Wire Twisted Shielded Wire Wire with Overbraiding MI Cable Multipair Thermocouple Wire Types,Duplex Insulated Thermocouple Wire,Metal Sheathed Thermocouple Wire,What is thermocouple wire? Thermocouple wire is a cable made from two dissimilar metals for the purpose of measuring temperature, Thermocouple wire is typically used to connect a thermocouple to a sensing device Data Communications and Coax Cable, wire, thermocouple wire,SLE, Insulated thermocouple wire extension grade, AWG, overbraid, overbraided Electronic Component Products that connect protect, power and switch Thermometers | Load Cells | Magnetic Flow Meters Panel Meters | Pressure Gauges | Pressure Transducers,RTD | Signal Conditioners | Strain Gauges | Temperature Controllers Temperature Labels | Temperature Measurement, Temperature Transmitters | Thermistors Thermocouple | Thermocouple Wire MINERAL INSULATED RTD CABLE MINERAL INSULATED THERMOCOUPLE CABLE สายไฟ ทนไฟไหม้ BETAflam? FR MI Cable / Single Core,สายไฟ ทนไฟไหม้ ASIA,Bangkok, Thailand,Singapore, Malaysia,Taiwan, Electricity TRIPLEX, PUR-Kabel, halogenfrei, Installationskabel, cable,Industrial Computer thailand, Electronic Component Products that connect, สายเคเบิลอาคาร (Building cable), extension grade, AWG, สายไฟส่วนขยาย (Extension cord), สายเคเบิลอาคาร (Building cable), mittelspannung, niederspannung, kabelsysteme, Spezialkabel, PVC, E 30, E 90, FE 180, FE 0, สายเคเบิลอาคาร (Building cable), schweiz, Studer Services, สายเคเบิล (Network patch cables), สายไฟฟ้าใช้ต่อสาย (Inter connect wire), mittelspannungskabel, niederspannungskabel, netzkabel, สายเคเบิลใช้ความร้อน (Heating cable), รอกม้วนสายเคเบิล (Cable reels), mittelspannungskabel, niederspannungskabel, netzkabel, เครื่องบังเหียนรัดสายไฟบนแผง (Panel wiring harness), Snow Melting, Electric Heat Cable, BETAflam® FR MI Cable / Multicore Power and Control, protect, power and switch, Temperature Labels | Temperature Measurement, cables in thailand, sattel in thailand,betaflam, สายเคเบิลเรือดำน้ำ (Submarine cable), betaflam fr,cables PVC, สายเคเบิลเปลือย (Bare cable), Metal Sheathed Thermocouple Wire,What is thermocouple wire?, Maintaining Process Fluid Temperatures, สายเคเบิลเรือดำน้ำ (Submarine cable), Thermocouple cable with a choice of PVC, PTFE, สายเคเบิลอาคาร (Building cable), Electric Heat Tracing, MI Cable, Tank Heater, insulated wiring, สายไฟฟ้าใช้ต่อสาย (Inter connect wire),
Company Profile
Products
News
Certificate
contact us
 
  
 
  
 

Home  domain names Catalog Request  domain names  Customer Support  email addresses Site References  web hosting   JOBs  web tools Links  help
Personal Domains
Products

  ÖPVC-JZ PVC-insulated control cable, flexible cores with imprinted numbers
     
     




Applications

Flexible OPVC control cables are used as power , and connecting cables in mechanical engineering for tooling machinery, control units, production lines, transportation equipment, conveyor and assembly lines, control desks as well as in plant construction, for office machines and in heating, air conditioning and ventilation systems
These cables are suitable for installation in dry, moist and wet rooms, mot however for outdoor or underground installation.
A green-yellow protective earth conductor is included in the outer layer of all cables of 3 or more cores.
The other cores are black with sequential numbering imprinted in white, commencing with no.1 at the centre and counting outwards. The print consists of numerals repeated throughout the length of the core. Each designation consists of a line underlining this number thus designating the direction of reading and preventing confusion between the individual number designations .
The imprint repeated approximately every 20 mm ( max. 50 mm according to VDE 0293 ) to assure visible identification even for short lengths of stripped insulation.

Characteristic features

Installation and identification of individual conductors made easier by the imprint of sequential numbering.
First-class mechanical properties and high flexibility of the cable are optimised by the design and construction using special PVC compounds for conductor insulation and sheath.

Durability

The PVC sheath is largely resistant to oils (depending on the type of oil), excluding VDE 0472 part 803.
Chemical resistance for PVC refer also to the Table of Technical Guidelines.



Cable design

Construction designed on the basis of DIN VDE
0245, 0250 and 0281
Conductor :plain Cu wires, flexible
Construction :according to VDE 0295 Class 5
of conductor and IEC 228 Class 5, refer also
of Technical Guidelines
Insulation : core insulation of special PVC
Compound
Fication white according to VDE 0293
Protective earth : green-yellow in the outer layer
Conductor:
Type of lay-up : cores laid-up in layers of
Optimum pitch
Sheath : sheath material from special
PVC compound
Sheath colour : standard colour grey

Note
Other cross sections and core configurations manufactured upon request.
OPVC-JZ also available with red or blue cores upon request.



Technical Data


Conductor resistance at 20°C: according to VDE 0295 Class 5 and IEC228 Class 5 for multi-stranded
                                                 conductors, refer also to Technical Guidelines.
Temperature at the core max.:+ 70°C in operation of a short circuit
Insulation resistance min. : 20 M km
Rated voltage U./U : 300 /500 V
Test voltage AC,50 Hz :3000v
Breakdown voltage min : 6000V
Minimum binding radius
up to 12 mm diameter : 10 cable diameter
> 12 mm diameter : 15 x cable diameter
Temperature range
Mobile : - 5°C to + 70°C
Fixed : -40°C to + 80°C
Radiation resistance : 80 Mrad (80 x 106 cj/kg)
Testing: according to DIN VDE 0472 and IEC regulations
Flame test : test class B according to
VDE 0472 part 804 and IEC 332-1
PVC characteristics : self-extinguishing and Flame-retardant



Dimensions

Reference
Approx.
Outer
Diameter
In mm
Copper
Weight

Kg/km

Approx.
Cable weight

Kg/km

Part no.
02...
Type
No. of conductors
Nominal cross
section mm2
ÖPVC-OZ
2x0.5

5.2

9.6

38

ÖPVC-JZ
3x0.5

5.5

14.4

45

 
5x0.5

6.6

24.0

68

 
6x0.5

7.1

28.8

77

 
7x0.5

7.3

33.6

81

 

10x0.5

9.2

48.0

127

 
12x0.5

9.6

58.0

138

 

14x0.5

10.0

67.0

152

 
18x0.5

11.3

86.0

197

 
21x0.5

12.0

101.0

232

 
24x0.5

12.9

115.0

254

 
25x0.5

13.2

120.0

166

 
30x0.5

14.3

144.0

320

 
34x0.5

15.2

163.0

380

 
40x0.5

16.5

192.0

430

 
50x0.5

17.5

240.0

512

 
61x0.5

19.8

293.0

610

 
100x0.5

24.5

480.0

986

 
ÖPVC-OZ
2x0.75

5.6

14.4

51

ÖPVC-JZ
3x0.75

5.9

21.6

68

 
4x0.75

6.8

28.8

80

 
5x0.75

7.8

36.0

102

 
6x0.75

8.0

43.2

116

 
7x0.75

8.3

50.5

122

 
8x0.75

9.4

58.0

136

 
9x0.75

9.8

65.0

158

 
10x0.75

11.0

72.0

190

 
12x0.75

11.2

86.0

203

 
15x0.75

11.8

108.0

248

 
16x0.75

12.2

115.0

267

 
18x0.75

13.0

130.0

280

 
20x0.75

13.7

144.0

287

 
25x0.75

15.7

180.0

395

 
32x0.75

16.3

230.0

462

 
34x0.75

17.3

245.0

498

 
40x0.75

19.6

288.0

613

 
41x0.75

20.0

296.0

634

 
50x0.75

21.0

360.0

780

 
61x0.75

21.9

439.0

904

 
65x0.75

22.6

468.0

942

 
ÖPVC-OZ
2x1

6.5

19.2

63

ÖPVC-JZ
3x1

7.0

29.0

74

 
4x1

7.8

38.4

98

 

5x1

8.8

48.0

118

 
6x1

9.4

58.0

130

 
7x1

9.4

67.0

141

 
8x1

11.2

77.0

165

 
9x1

11.6

86.0

200

 
10x1

12.2

96.0

230

 
12x1

12.4

115.0

246

 
14x1

12.8

134.0

291

 
16x1

13.7

154.0

310

 
18x1

14.3

173.0

382

 
19x1

15.0

183.0

402

 
20x1

15.5

192.0

411

 
25x1

17.9

240.0

520

 
26x1

18.4

250.0

552

 
34x1

20.4

326.0

678

 
36x1

20.6

346.0

716

 
41x1

21.9

394.0

812

 
42x1

22.3

403.0

836

 
50x1

24.2

480.0

940

 
56x1

24.8

538.0

938

 
61x1
26.0

586.0

1070

 
65x1
26.5

624.0

1172

 
ÖPVC-OZ
2x1.5

6.9

29.0

82

ÖPVC-JZ
3x1.5

7.6

43.0

104

 
4x1.5

8.3

58.0

120

 
5x1.5

9.4

72.0

144

 

6x1.5

10.2

86.4

174

 
7x1.5

10.2

101.0

190

 
8x1.5

11.8

115.0

218

 
9x1.5

12.4

129.0

243

 
10x1.5

12.8

144.0

276

 
11x1.5

13.0

158.0

305

 
12x1.5

13.2

173.0

314

 

14x1.5

14.0

202.0

338

 
18x1.5

15.8

259.0

482

 
20x1.5

17.0

288.0

563

 
21x1.5

17.2

302.0

583




Note
Cables without green-yellow protective earth conductor designated with O instead of J.

Note
Other cross sections and core configurations manufactured with red or blue cores upon request.
 
 


<< Back to Products Page



web hosting
 
 
See more detail
Partner Links:
9apartment.com (Thai version) | 9apartment (English version) |
Privacy policy