Products
| |
LiY |
PVC-insulated
hook-up Wires according to VDE 0812 |
| |
H05V-U/-K |
PBV-insulated Wiring cable
according to VDE 0281 |
| |
H07V-U/-R/-K |
PVC-insulated single-core
cable according to VDE 0281 |
|

|
 |
Applications |
LiY PVC-insulated hook-up wires according
to VDE 0812
These flexible hook-up wires with an insulating
sheath of PVC are primarily used in conjunction
with movable assemblies and components,
and for other connections inside the equipment
which are subjected to a binding load
by repeated movement. In addition to this,
these wires are used for interconnecting
and wiring telecommunications equipment
and electronic assemblies such as for
example network switching cabinets, amplifier
and selector racks, and measuring equipment
in telephone switching, information processing
equipment and clock centres.
These hook-up wires are not approved for
power installation applications external
to the equipment.
H05V-U/-K PVC- insulate wiring cable according
to VDE 0281 part 3, HD 21.3 S3 and IEC
227-3
These flexible PVC-insulated wiring cables
are used for the internal wiring of equipment
as well as for protected installation
in and to lighting fixtures, in tubes,
in conduit, on and under plaster although
only for bell circuits and signal systems.
H07V-U/-R/-K PVC-insulated single-core
cable according to VDE 0281 part 3, HD
21.3 S3 and IEC 227-3
These PVC-insulated single-core cables
are used for the internal wiring of equipment,
switching systems and distributors as
well as for the protected installation
in and to lighting fixtures with a rated
voltage up to 1000 V alternating current
of a direct voltage up to 750 V, earthed.
These cables are suitable for installation
in dry rooms, switching and distribution
systems, in conduit, on, in and under
plaster as will as in closed installation
ducts.
Note ( for H07V )
These single-core cables may not be
used for direct installation on flatbed
bodies, ducts or tanks.
Approved for use as potential-compensating
cable directly on, in and underneath plaster
as well as on flatbed bodies or similar.
|
 |
Cable design
Construction designed according
to VDE 0812 and VDE 0281 part 3
LiY ( tinned ) according to VDE 0812
Conductor : Cu stranded conductor, tinned
Construction of : according to VDE 0812
conductor
Insulation : PVC, compound type Y12
according to
VDE 0207 Part 4
Core identification : see table opposite
H05V-U,H05V-K according to VDE 0281
part 3
Conductor :Cu wires, plain, solid conductor
or flexible
Construction of : according to VDE 0295
Class1 or 5,
conductor and HD 383
Insulation : PVC, compound type Y/1
according to
VDE 0207 part 4
Core designation : according to VDE
0293,refer also to table
opposite
H07V-U,H07V-R,H07V-K according to VDE
0281 part 3
Conductor : Cu wires, plain, solid-core,
multi-stranded
or flexible
Construction of : according to VDE 0295
Class 1,2 or 5,
conductor and HD 383
Insulation : PVC, compound type YI1according
to
VDE 0207 part 4
Core designation : according to VDE
0293, refer also to table
Opposite
Note
Single-core conductor with double insulation
(LiYY ), heat resistant and cross-linked
versions available upon request.
|
 |
Technical Data
Conductor resistance : LiY according
to VDE 0812, H05V
at 20° C and H07V according to VDE
0295
and IEC 228
Temperature at the core :+ 70° C in
operation
Insulation resistance
LiY min. : 20 M
Ω • km
H05/H07 min. : 20 M
Ω • km
Operating voltage Ueff
LiY 0, 14 mm2 : 500 V
0, 25 to 1,5 mm2 : 1200 V
Test voltage AC, 50 Hz
LiY 0, 14 mm2 : 1200 V
0,25 to 1,5 mm2 : 2500 V
Rated voltahe Uo /U
H05V : 300 / 500 V
H07V : 450/750 V
Test voltage AC, 50 Hz
H05V : 2000 V
H07V : 2500 V
Temperature range
mobile : - 5°C to +70°C
fixed : - 30°C to + 70°C
Bending radius up to
10 mm diameter : 10 x cable diameter
> 10 mm diameter : 15 x cable diameter
Radiation resistance : 80 Mrad (80x106
cJ/kg )
Testing according to DIN 0472 and IEC
regulations
Flame test : test class B according to
VDE 0472 part 804 and IEC 332-1
PVC characteristics : self-extinguishing
and flame-retardant
|
 |
Dimensions
| Reference |
Approx.
Outer
Diameter
In mm
|
Copper
Weight
Kg/km
|
Approx.
Cable weight
Kg/km
|
| Part no.
05...
Type
|
Nominal
cross section
Type mm2
|
| LiY, tinned |
|
|
|
|
| |
0.14 |
1.20 |
1.4 |
3.1 |
| |
0.25 |
1.40 |
2.4 |
4.2 |
| |
0.50 |
1.95 |
4.8 |
7.1 |
| |
0.75 |
2.15 |
7.2 |
9.8 |
| |
1.0 |
2.25 |
9.6 |
13.7 |
| |
1.5 |
2.75 |
14.4 |
18.5 |
| |
|
|
|
|
| H05V-U / H05V-K |
|
|
|
|
| H05V-U |
0.5 |
2.3 |
4.8 |
7.0 |
| |
0.75 |
2.5 |
7.2 |
10.0 |
| |
1.0 |
2.7 |
9.6 |
14 |
| |
|
|
|
|
| H05V-K |
0.5 |
2.5 |
4.8 |
7.5 |
| |
0.75 |
2.7 |
7.2 |
10.5 |
| |
1.0 |
2.8 |
9.6 |
15.0 |
| |
|
|
|
|
| H07V-U/H07V-R/H07V-K |
|
|
|
|
| H07V-U |
1.5 |
3.2 |
14.4 |
19 |
| |
2.5 |
3.9 |
24.0 |
30 |
| |
4 |
4.4 |
38.0 |
45 |
| |
6 |
5.0 |
58.0 |
63 |
| |
10 |
6.4 |
96.0 |
110 |
| |
|
|
|
|
| H07V-R |
1.5 |
3.3 |
14.4 |
19 |
| |
2.5 |
4.0 |
24.0 |
30 |
| |
4 |
4.6 |
38.0 |
45 |
| |
6 |
5.2 |
58.0 |
63 |
| |
|
|
|
|
| H07V-R |
10 |
6.7 |
96.0 |
110 |
| |
16 |
7.8 |
154.0 |
165 |
| |
25 |
9.7 |
240.0 |
264 |
| |
35 |
10.9 |
336.0 |
360 |
| |
50 |
12.8 |
480.0 |
490 |
| |
70 |
14.6 |
672.0 |
720 |
| |
95 |
17.1 |
912.0 |
1015 |
| |
120 |
18.8 |
1152.0 |
1250 |
| |
150 |
20.9 |
1440.0 |
1500 |
| |
185 |
23.3 |
1776.0 |
1900 |
| |
240 |
26.6 |
2304.0 |
2440 |
| |
300 |
29.6 |
2880.0 |
3100 |
| |
|
|
|
|
| H07V-K |
1.5 |
3.4 |
14.4 |
22 |
| |
2.5 |
4.1 |
24.0 |
30 |
| |
4 |
4.8 |
38.0 |
66 |
| |
6 |
5.3 |
58.0 |
112 |
| |
10 |
6.8 |
96.0 |
172 |
| |
16 |
8.1 |
154.0 |
268 |
| |
25 |
10.2 |
240.0 |
363 |
| |
35 |
11.7 |
336.0 |
510 |
| |
50 |
13.9 |
480.0 |
700 |
| |
70 |
16.0 |
672.0 |
960 |
| |
95 |
18.2 |
912.0 |
1295 |
| |
120 |
20.2 |
1152.0 |
1590 |
| |
150 |
22.5 |
1440.0 |
2085 |
| |
185 |
24.9 |
1770.0 |
2450 |
| |
240 |
28.4 |
2304.0 |
3160 |
|
 |
Standard core colours available
Liy : black, red, blue, pink, grey,
yellow, green, brown, white, violet
H05V : black, blue, brown, grey, orange,
pink, red, turquoise, violet, white and
two-colour combinations
H07V : black, blue, brown, grey, orange,
pink, red, turquoise, violet, white. Two-colour
combinations are not permitted except
for green-yellow. |
 |
Note
Single-core conductor with double insulation
(LiYY), heat resistant and cross-linked
versions available upon request.
|
 |
| |
<< Back to Products Page
|
|
 |
|
 |
|